IQFDA30
www.snellgroup.com
Operation Using the RollCall Control Panel
Issue 1 Rev 2
Page 21
©
2013 Snell Limited
5.6 RollTrack
The RollTrack screen allows information to be sent, via the RollCall™ network, to other
compatible units connected on the same network.
5.6.1 Disable All
When checked, all RollTrack items are disabled.
5.6.2 Index
This slider enables up to 16 RollTrack outputs to be setup. Dragging the slider selects the
RollTrack Index number, displayed below the slider. Clicking the
P
button selects the default
preset value.
5.6.3 Source
This slider enables the source of information that triggers the transmission of data to be
selected. Dragging the slider selects the RollTrack source, displayed below the slider.
Clicking the
P
button selects the default preset value. When no source is selected,
Unused
is
displayed.
Unused
No RollTracks sent.
Input N OK
Valid serial data input received.
Input N None
No serial data input received.
Input N Bitrate 270
Received bitrate is 270 Mbit/s.
Input Bitrate 1.5
Received bitrate is 1.5 Gbit/s.
Input N Bitrate 3G
Received bitrate is 3 Gbit/s.
Input N Bitrate Un.
Received bitrate is unknown.
TX N Bias OK
LASER Bias current within limits.
TX N Bias High
LASER Bias current above limits.
TX N Bias Low
LASER Bias current below limits.
RX N Power OK
Receive power is within limits.
RX N Power High
Receive power is above limits.
RX N Power Low
Receive power is below limits.