SHDSDA2
OPERATION
SHDSDA2
Version 1 Issue 3
030402
10
Rollcall Monitoring Features
n
Module Infrastructure:
General Alarm
Supply Voltage Levels
Board Temperature
n
Incoming Signal analysis:
Input Status.
Line Standard
Frame Type
Frame Rate
n
CRC Error analysis:
CRC Error Count
CRC Error Total
CRC Reset
n
Bias/EQ – The value in this field is a guide to
the strength of equalisation that is being
applied to the input signal for longer cable
runs. The lower the value, the less equalisation
is being employed. It is intended as a guide for
troubleshooting the system. It should be noted
that when an equalisation of 100% is shown, it
doesn’t necessarily mean that the maximum
input cable length has been reached. As soon
as CRC errors are being reported then the
input cable length should be decreased until an
error free signal can be received.