background image

CVR250

SECTION 4

CVR250OPS

20/10/06

www.snellwilcox.com

Version 1 Issue 4

4.5

CVR250

Menu System

Logging

Log Input Status
Log Input Standard
Log Reference  
Log EDH Errors 
Log Temperature 

Setup

Encoder...
Genlock...
Pattern...
GPI...
VI Blanking...
RollTrack...
Logging...
Preset Unit

Status

Status Display...
GPI Delay
Unit Temperature
Software Version
Serial Number
Build Number
Restart

Serial Number

Serial No
xxxxxxx

         OK

Build Number

Build Number
xxxxxxx

         OK

Software Version

Software Version
x.x.x

         
         OK

GPI   Delay

GPI Delay
gpi delay

         OK

Unit Temperature

OK
Near Limit
Overheating

Status Display

Default Display

Status Display 1
Status Display 2
Status Display EDH
Reset EDH Status

Output

625 Output
525 Output
625 Standard Setup...
525 Standard Setup...
Default Output...

625

AutoDetect

Default Output

Black
Pattern
Freeze

625

AutoDetect

625 Standard Setup

PAL
PALN
SECAM

625

AutoDetect

525 Standard Setup

NTSC
PALM
NTSCJ
N443

Clear

Clear M1
Clear M3
Clear M5
Clear M7

Clear M2
Clear M4
Clear M6
Clear M8

Name

Name M1
Name M3
Name M5
Name M7

Name M2
Name M4
Name M6
Name M8

Recall

Recall M1
Recall M3
Recall M5
Recall M7

Recall M2
Recall M4
Recall M6
Recall M8

Save

Save M1
Save M3
Save M5
Save M7

Save M2
Save M4
Save M6
Save M8

Memories

Recall...
Clear...

Save...

Name...

Name 1 to 8

Name 1 to 8

Clear
Preset

memory 1 to 8 name

OK

Input

Input Select...
Input Standards...
Freeze Input
Decoder...

NTSC Hue

0 deg

Preset

NTSC Hue

Decoder

Auto Gain Control
Auto Chroma Control 
NTSC Hue
PAL Line 23...
NTSC Line 21/283...

Aperture A
Aperture B

Aperture

H Enhance

Mid  Off
Mid Low
Mid Med
Mid High

Hi  Off

Hi Low

Hi Med

Hi High

V Enhance

V Enhance  Off
V Enhance Low
V Enhance Med
V Enhance High

Enhance

Enable Enhance
Aperture...
V Enhance...
H Enhance...

Features

Enhance..
Size...
Noise Reduce...
RGB Legaliser

Noise Reduce

Noise Reduce
Recursive Level...
Recursive Threshold
Sparkle Filter
Median Filter
Split Screen..

Recursive Level

C  Off
C Low
C Medium
C High

Y  Off

Y Low

Y Medium

Y High

Recursive Threshold

5

Preset

Recursive Threshold

Split Screen

Split Screen Off
Left Right
Top Bottom

Size

Size Enable
Horz Size
Vert Size
Aspect Ratio...

Zoom

Pan

Tilt

Border...

Top Blank/Bottom

0 Lines

Preset

Top Blank/Bottom

Input Blank

Top Blank

Bottom

Tilt

25.0

Preset

Tilt

Pan

30.0

Preset

Pan

Set Color

Border Red
Border Green
Border Blue

Border Red/Green/Blue

0

Preset

Border Red/Green/Blue

Border

Input Blank...
Color

Black

Set Color...

Zoom

150.0%

Preset

Zoom

Horz Size

150.0%

Preset

Horz Size

Vert Size

150.0%

Preset

Vert Size

Var. Aspect Ratio

2.750

Preset

Var. Aspect Ratio

Aspect Ratio

Var. Aspect Ratio 
Normal  
4:3 > 16:9 PB 
4:3 > 14:9 PB 
4:3 > 16:9 FH 
16:9 LB > 4:3
16:9 LB > 14:9 LB 
16:9 FH > 4:3
16:9 FH > 14:9 
16:9 FH > 4:3 LB

CVR250 MAIN  MENU

Input...
ProcAmp...
Status...
Setup...

Output...

Features...

Memories...

Chroma Gain

0.0 dB

Preset

Chroma Gain

Black Level

0 mV

Preset

Black Level

YC Timing

0ns

Preset

YC Timing

Picture Position

0ns

Preset

Picture Position

625

AutoDetect

Timing

Timing Enable
Picture Position
YC Timing

625

AutoDetect

NTSC Line 21/283

Process as video
Process as data
Blank line 21/283

625

AutoDetect

PAL Line 23

Process as video
Process as data
Blank line 23

Preset

Luminance Gain

0.0 dB

Luminance Gain

Proc Amp

Proc Amp Enable

Luminance Gain
Black Level
Chroma Gain
RGB Legaliser
Timing...

625

AutoDetect

SECAM Options

Notch Disable
Bottles Enable
Carrier Disable
Chroma Filt Disable

Encoder

VITS 625 Insert
VITS 525  Insert
Min Blanking 625
Min Blanking 525
PAL-I Blanking
SECAM Options...
Pass Vertical Data

H Phase

0 ns

Preset

H Phase

SC Phase

0.0 Deg

Preset

SC Phase

Genlock

Genlock Enable
PAL H Phase
PAL SC Phase
PALN H Phase
PALN SC Phase
SECAM NTSC443 Phase
NTSC H Phase
NTSC SC Phase
PALM H Phase
PALM SC Phase 

RollTrack Mode

Not Used
Delay
Input Loss
Input Restore

RollTrack 1-10

RollTrack Unit
RollTrack Params
RollTrack Mode...

RollTrack

RollTrack 1...
RollTrack 2...
RollTrack 3...
RollTrack 4...
RollTrack 5...
RollTrack 6...
RollTrack 7...
RollTrack 8...
RollTrack 9...
RollTrack 10...

RollTrack Params

RollTrack Params

Clear
Preset

Rollparams 1-10

OK

RollTrack Unit

RollTrack Unit

Clear
Preset

Rollunit 1-10

OK

VI Blank 525...
VI Blank 625...

VI Blanking

VI Blank 625

Blank All
Line 6
to
Line 22
Line 335

Pass All

Line 318

to

Line 334

VI Blank 525

Blank All
Line 10
to
Line 20

Pass All

Line 273

to

Line 282

Pattern

Pattern Enable
Black
75% Color Bars
100% Color Bars
MultiBurst
100% Ramp

GPI 1, 2 Open

OFF
Memory 2
Memory 4
Memory 6
Memory 8

Memory 1
Memory 3
Memory 5
Memory 7

OFF
Memory 2
Memory 4
Memory 6
Memory 8

Memory 1
Memory 3
Memory 5
Memory 7

GPI 1, 2 Close

GPI

GPI1 Open...
GPI2 Open...
GPI2 Select

1 Close...
2 Close...

Input Standards

SDI 625
SDI 525
PAL
PALN

NTSC

PALM
N443

SECAM

NTSCJ

Input Select

Serial Digital A

Serial Digital B
Composite A

Composite B
YC

GPI 2
Audio Delay Flag

GPI 2 Select

Содержание Kudos Plus CVR250

Страница 1: ...www snellwilcox com Snell Wilcox Ltd Southleigh Park House Eastleigh Road Havant Hants PO9 2PE United Kingdom For General Enquiry s contact Tel 44 0 2392 489000 Fax 44 0 23 9245 1411 For Technical ass...

Страница 2: ...Es befinden sich keine vom Benutzer zu wartenden Teile im Ger teinneren Dieses Ger t sollte nur von geschultem Personal gewartet werden Um das Risiko eines Elektroschocks zu reduzieren setzen Sie das...

Страница 3: ...g Om enheten har tv huvudsakliga elf rs rjningar s kerst ll att b da str mkablarna som r inkopplade i enheten arbetar fr n samma fas S CAUTION RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS NO USER SERVI...

Страница 4: ...imenta o com ficha IEC f mea standard num extremo e uma ficha IEC macho standard no extremo oposto Se for necess rio substituir ou alterar alguma destas fichas dever remove la e elimina la imediatamen...

Страница 5: ...wing methods of installation must be used Place the unit on a suitably specified and installed rack shelf and secure the product to the rack via the front rack ears or Fit the unit using the rear rack...

Страница 6: ...os and the rural outdoor environment far away from railways transmitters overhead power lines etc E4 The applicable environment is stated in the Technical Profile section of the product operation manu...

Страница 7: ...with Version 6 6 8 of the software Manufacturers Notice Copyright protection claimed includes all forms and matters of copyrightable material and information now allowed by statutory or judicial law o...

Страница 8: ...Output Connections 3 3 Communication Connections 3 4 Matching the Front Panel to a Gateway Address 3 5 4 Operation The Control Panel 4 1 Browse 4 3 RollCall Menu System 4 5 Operation of the Front Pan...

Страница 9: ...4 25 Control 4 25 Proc Amp 4 26 Noise Reduction 4 27 Enhance 4 28 Size 4 29 Decoder 4 30 Encoder 4 31 Genlock 4 32 Memories 4 33 RollTrack 4 34 GPI 4 35 Logging and Preset 4 36 VBI 4 37 Pattern 4 38...

Страница 10: ...ing monitored System Please provide a brief description of the system in which your S W equipment is currently being used Basic Tests Preset Unit Please use the Preset Unit function to return the sett...

Страница 11: ...Type Video Products i e Modular Kudos Plus and Alchemist Unit Serial Number Fault Spare Part Information please advise us how many units show this fault and the system layout showing all other manufac...

Страница 12: ...4 0 12 Manual Revision Record Date Version No Issue No Change Comments 090503 1 1 First issue released 200504 1 2 Std LED color corrected PSP New issue released 010305 1 3 Templates corrected New iss...

Страница 13: ...lization Where space and budget are at a premium nothing will outperform this budget unit The CVR250 is designed to integrate up to three IQ modules This powerful feature enables users to customize th...

Страница 14: ...l position half picture width continuously variable Vertical position half picture height continuously variable Picture timing Y C Timing 444 ns in steps of 148ns Picture Position phase 592 ns in step...

Страница 15: ...25 to 525 Linear mode 70 ms 625 to 625 1 39ms Size Off 525 to 525 1 35ms Size Off 525 to 625 Linear mode 58 ms 625 to 625 70ms Size On 525 to 525 58ms Size On Return Loss Inputs better than 35 dB to 5...

Страница 16: ...age The power supplies are auto switching for input voltages in the ranges of 100 V to 250 V nominal No voltage adjustment procedure is required CAUTION THIS UNIT MUST NOT BE OPERATED WITHOUT AN EARTH...

Страница 17: ...burst level into 75 Ohms SDI A B These are the 2 SDI inputs to the unit via BNC connectors Reference Inputs 525 and 625 When suitable signals are connected to these inputs the video output of the unit...

Страница 18: ...se BNC connectors Output level is standard 1V p p into 75 Ohms SDI 1 2 These are the 2 SDI outputs of the unit via BNC connectors Y C Separated Output A Y C S VHS Hi 8 output signal is available via t...

Страница 19: ...ector may also be used as a RS422 port For more information see Section 5 Modes of Operation RollCall This single BNC connector allows the unit to be connected to the RollCall network communications s...

Страница 20: ...panel Note that this address will only be read at unit power up Position 0 on the left hand switch will disable the RollCall function on the unit Addresses 00 to 0F are pre arranged All other positio...

Страница 21: ...the chosen function For example holding down the Pattern button will reveal the Pattern selection menu Note that some buttons do not have an ON OFF function e g SETUP in this case a momentary push wi...

Страница 22: ...ha numerics may be changed using the spinwheel If a menu title is followed by three dots e g Input Standards this indicates that a further sub menu is available for selection Display Window The displa...

Страница 23: ...ows the RollCall network Note the browse button will remain illuminated to indicate that the unit being controlled is not the default unit This allows connections to be made to other RollCall network...

Страница 24: ...box The symbols used are shown below This symbol represents a gateway to a module This indicates that the unit is currently connected to this control panel Pressing the adjacent button will disconnect...

Страница 25: ...Border Blue Border Red Green Blue 0 Preset Border Red Green Blue Border Input Blank Color Black Set Color Zoom 150 0 Preset Zoom Horz Size 150 0 Preset Horz Size Vert Size 150 0 Preset Vert Size Var...

Страница 26: ...y of these buttons will reveal the Input Menu Note that these buttons are mutually exclusive and only one of the inputs may be selected Input This function allows the input parameters to be set Input...

Страница 27: ...will be at a line rate of 625 if the detected input signal has a line rate of 625 similarly the output signal will be at a line rate of 525 if the detected input signal has a line rate of 525 NTSCJ W...

Страница 28: ...oDetect NTSC Line 21 283 Process As Video Process as Data Blank Line 21 283 Process As Video When enabled line 21 283 of the input signal will be processed and the ProcAmp controls will effect Line 21...

Страница 29: ...pictures that contain limited amounts of fast motion and allows a picture to be displayed with a minimal amount of motion induced aliasing effects V Enhance This allows Vertical enhancement to be app...

Страница 30: ...e 625 Standard Setup 625 AutoDetect 625 Standard Setup PAL PALN SECAM This selects the 625 line composite standard to be used when operating in the 625 line output line standard 525 Standard Setup 625...

Страница 31: ...Preset Black Level Selecting Preset returns the setting to the calibrated value of 0 C GAIN Chrominance Gain Pressing this button will reveal a numerical readout display for the gain of the chrominanc...

Страница 32: ...Timing 625 AutoDetect Timing Timing Enable Picture Position YC Timing Timing Enable When this item is selected the timing values will be enabled Picture Position Selecting this item displays the posi...

Страница 33: ...e M2 Save M4 Save M6 Save M8 Selecting a memory location will save the settings and store them in the selected memory location Clear This will reveal a list of the memory locations Clear Clear M1 Clea...

Страница 34: ...y showing the horizontal timing of the output signal relative to the reference sync signal in nanoseconds Rotating the spin wheel will adjust this value H Phase 0 ns Preset H Phase The range is 113 s...

Страница 35: ...this insertion takes priority over the Pass Vertical Data function Min Blanking 625 When selected the blanking width will be reduced to the minimum allowed by CCIR 624 for the 625 standard Min Blanki...

Страница 36: ...1 Memory 3 Memory 5 Memory 7 OFF No response Memory 1 to 8 The unit will revert to the setup stored in the selected memory location 1 Close GPI 1 Close and 2 Close GPI 2 Close This function determine...

Страница 37: ...passed Line 10 to 20 Line 273 to 262 Selecting lines from this list will blank the VBI data on that line If the line is unselected the VBI data on that line will be passed through unprocessed For the...

Страница 38: ...t and the spinwheel used to select the character To save the new text press the OK button It should be noted that this is the only way to save the new text as any other button function will return to...

Страница 39: ...logging device Log Input Standard When activated the input line standard will be available for the logging device Log Reference When activated a presence or loss of reference signal condition will be...

Страница 40: ...0 Preset Vert Size The range of control is from 50 to 200 in 0 1 steps Preset is to 100 Aspect Ratio This function allows the input to output aspect ratio to be changed Aspect Ratio Var Aspect Ratio...

Страница 41: ...k Top Blank Bottom Top Bottom Blank This function allows active input picture lines to be blanked out at the top and or the bottom of the picture and replaced with a fixed black signal Top Blank Botto...

Страница 42: ...ve when the Sparkle filter is enabled When selected sparkle concealment is enabled that employs a threshold controlled 3 dimensional median filter This permits the removal of picture disturbances that...

Страница 43: ...n forced because of an input signal failure the words will be prefixed by an asterisk e g Pattern Black or Freeze If the proc amp controls are not preset then UnCal appears in the display Status Displ...

Страница 44: ...imit The cause should be investigated and rectified Software Version Software Version Software Version x x x OK Selecting this item reveals a display showing the version of the software in the module...

Страница 45: ...e decoded and will produce an unstable lock To force the unit to decode only one standard check that standard and uncheck all others Note that at least one standard must be selected if an attempt is m...

Страница 46: ...ain may be adjusted by 6 dB in steps of 0 1 dB Selecting Preset returns the setting to the calibrated value of 0 Black Level By using the scroll bar the pedestal may be adjusted by 100 mV in steps of...

Страница 47: ...ith edge of reception signals from satellite feeds impulse noise or drop outs from tape recorded signals Median When selected sparkle concealment is enabled that employs a threshold controlled 3 dimen...

Страница 48: ...t motion to be displayed with minimal blurring effects and maximum sharpness Aperture B is suited for pictures that contain limited amounts of fast motion and allows a picture to be displayed with a m...

Страница 49: ...0 1 steps and preset is to 100 Zoom This allows the picture size to be changed while maintaining the aspect ratio The range of control is from 50 to 200 in 0 1 steps and preset is to 100 Pan The amoun...

Страница 50: ...adjusted by 30 in steps of 1 Selecting Preset returns the setting to the calibrated value of 0 PAL Line 23 Process As Video When enabled line 23 of the PAL input signal will be processed as active pic...

Страница 51: ...king width will be reduced to the minimum allowed by CCIR 624 for the 525 standard SECAM Options Notch Filter Disable When selected the SECAM luminance notch filter will be disabled Preset Unit is to...

Страница 52: ...9 lines in steps of one cycle of subcarrier Genlock Offset Phase PAL ns Scroll Bar also PALN NTSC PALM These items allow adjustment of the horizontal timing of the output signal relative to the refere...

Страница 53: ...eturn the text to the default name This function clears the memory location and returns to the default preset setting This function saves the current settings of all items at a memory location This fu...

Страница 54: ...Wilcox agent The unit address has three sets of numbers For example 0000 DB 02 The first set 0000 is the network segment code number The second set DB is the number identifying the enclosure mainfram...

Страница 55: ...n changes from open to closed OFF No response Memory 1 to 8 The unit will revert to the setup stored in the selected memory location Select GPI2 Function Input Enable When Input Enable is selected GPI...

Страница 56: ...ormation about the 5 listed parameters can be made available to a logging device that is attached to the RollCall network Preset Unit Selecting this item sets all functions that are available at user...

Страница 57: ...o the output by checking the appropriate box For line 23 controls see page 4 30 All This section allows all vertical interval lines to be selected and either passed to or blanked from the output signa...

Страница 58: ...10 06 www snellwilcox com Version 1 Issue 4 4 38 Pattern This function allows various patterns to be used as the output signal Pattern Enable When this item is active a pattern selected from the list...

Страница 59: ...ines Input Bottom Blank Lines This function allows active input picture lines to be blanked out at the bottom of the picture and replaced with a fixed black signal The range of control is from 0 to 12...

Страница 60: ...it The cause should be investigated and rectified GPI Delay This displays the total audio delay through the unit in milliseconds It is comprised of the Audio Delay Offset and the measured video delay...

Страница 61: ...the input error detection handler EDH states are None No EDH present in the source OK Correct EDH detected Fail Error in the EDH detected N A Not applicable to this source type Err The number of EDH...

Страница 62: ...is a N443 composite signal Second Line Item 1 Ou snellwilcox local root Marketing Prodmg mt Data Encoder output signal standard PAL Output is a PAL composite signal PALN Output is a PALN composite si...

Страница 63: ...g the adjacent push button The spinwheel also allows continuously variable parameters e g Gain to be adjusted and the setting to be seen in the LCD window 3 Via a PC using the RollCall Templates All o...

Страница 64: ...Y gain setup SDI CVR250 STANDARDS CONVERTER scroll adjust home previous return hold for menu 625 525 C gain Note that only one of these configurations may be used at a time The following methods may b...

Страница 65: ...ed PC running Microsoft Windows 3 1x Windows 95 or Windows NT Either a RollCall PC card IQCPC or a RS232 to RS422 9 way converter fitted to the PC Connecting the hardware There are two choices for con...

Страница 66: ...xB TxA RxB RxA 1 6 2 7 3 8 4 9 5 9 way ribbon 1 6 2 7 3 8 4 9 5 N B Connector is a socket viewed from mating face Equivalently this is a plug viewed from the rear cable face For reference the A signal...

Страница 67: ...received Writes a current status file for configured units and allows the LogViewer program to display the information ROLLVIEW EXE This program displays the current status file written by ROLLLOG EX...

Страница 68: ...the Y Gain and Black Level buttons together 2 Select Yes to the front panel question Restart panel Are you sure 3 Hold down the Y Gain button to enter the setup mode 4 When the message Setup mode is d...

Страница 69: ...in the same way When the name has been set to that required press the SAVE function to save the name Note that to remove a character and leave a clear space in the text line the Clear function above...

Страница 70: ...ing of the display windows to set by rotating the spinwheel to the following modes OFF Backlight always Off Use this mode where ambient light level is high ON Backlight always On Use this mode where a...

Страница 71: ...els From the main menu select Set Password To enter the Supervisor level and set up a password proceed as follows 1 Power down the unit 2 Hold down the YC button and power up the unit Continue to hold...

Отзывы: