IQCSPI
SECTION 33c
IQCSPOPS
100305
www.snellwilcox.com
Version 1 Issue 8
33c.33
Track=nnnn:aa:pp*c*ii,m1,v1,s1,o1,65536
This sends the value formed by m1, v1+o1 and s1
to command c on the unit nnnn:aa:pp with unit type
ii. It expects to receive a reply, but ignores the
value.
Track=nnnn:aa:pp*c*ii,m1,v1,s1,o1,m2,v2,s2,o2
This sends the value formed by m1, v1+o1 and s1
to command c on the unit nnnn:aa:pp with unit type
ii. It expects to receive a reply with data mode m2,
and the numeric value v2+o2.
The user can enter anything they want within the
LogMessageHeader and the LogMessageValue.
However there is standard list of LogMessages:
INPUT=OK, INPUT=LOST, STD=625, STD=525,
STD+PAL, STD=NTSC, STD=PAL-M,
STD=AUTO, STD=STDERR, STD=UNKNOWN,
EXTREF=OK, EXTREF=N/A, EXTREF=LOST,
EDH=OK, EDH=FAIL, EDH=NONE, EDH=RESET,
ERRSEC=n, AUDIO=1-2-3-4-5-6-7-8,
AUDIO=---------------, POWER=OK, POWER=FAIL,
SN=n, FAULT=NONE, FAULT=FAIL:description,
MSG=Restarted, MSG=Restarted at, AES=OK,
AES=LOST:description, FREQ=nn kHz,
SOUND=OK, SOUND=LOW:description,
PICTURE=OK, PICTURE=FREEZE,
PICURE=BLACK
Substitution Strings
The format for these is
Stringn = StudioA
Where n is an integer and ‘StudioA’ is the string which
is substituted when the commands value is n.
The list must start with String0 and include every
number between that and the highest numbered
string.