Information Window 

 
This will display basic information about the status 
of the unit.  
 

Input 1: and Input 2:

    

 
This will show the status of the input. It can show:
 

  

SILENCE 

The input signal has been lost 

 
OK 

The  module  is  receiving  a  valid  input 
signal

 

 
Mode: 

Shows  whether  the  unit  is  in  single 
channel (1-CHANNEL) or two channel 
(2-CHANNEL) mode. 

 

 

 

Single Channel Mode 
 
 

 

 

Two Channel Mode 

Information 
Window 

Information 
Window 

Содержание IQADA01

Страница 1: ...atures 4 Technical Profile 5 INPUT AND OUTPUT CONNECTIONS 6 Analog IN 6 Analog OUT 6 25 Way D Type Connection Details for Connector 1 and Connector 2 7 CARD EDGE INDICATORS 9 RollCall PC Control Panel...

Страница 2: ...0 1A Single Dual Channel Analog DA Balanced D type Audio Connections Configurable for 1 input to 14 outputs or 2 inputs to 7 outputs per input IQADA0112 2 Single Dual Channel Analog DA Balanced D type...

Страница 3: ...style enclosure shown below IQ Enclosure order codes IQH3A E 0 IQH3A E P IQH3A 0 0 IQH3A 0 P Enclosure order codes IQH3A S 0 IQH3A S P O Style Enclosures Rear panels without the suffix A may only be...

Страница 4: ...work control monitoring intelligence and 2 Built in Intelligence 1 1 2 3 Silence Detect Gain Silence Detect Gain 4 5 6 7 1 2 3 4 5 6 7 Features Configurable for 1 input to 14 outputs or 2 inputs to 7...

Страница 5: ...stable for each input Functions Available via RollCall Gain Separate L and R 24 dB to 24 dB in 0 5 dB steps Silence Detect Level adjustable 15 to 25 dBu in 1 dB steps Warning Timer 1 to 60s for silenc...

Страница 6: ...e connectors For connection data consult the tables on page 7 Note that when configured as a single input fourteen output amplifier connector 1 should be used for the input signal Analog OUT All balan...

Страница 7: ...tput 2 23 Ground 7 Ground 24 Channel 7 Analog Audio Output 1 25 Channel 8 Analog Input By Function Pin No Description Connection 1 Chassis Ground Ground 2 Channel 1 Analog Audio Output 7 15 Channel 1...

Страница 8: ...ectors MALE CONNECTOR OUTPUTS FEMALE CONNECTOR INPUTS 25 Way Male D Type XLR Connections Solder Pin Side 16 19 22 25 2 5 8 11 1 3 4 6 7 9 10 12 13 14 15 17 18 20 21 23 24 XLR Connections Analog Audio...

Страница 9: ...inate if either input or the primary input when in single channel mode is missing D3 Power up or CPU fault Red This LED will illuminate during power up or indicate a CPU fault RV1 and RV2 These contro...

Страница 10: ...available Silence Level The level at which the signal is considered to have dropped to silence may be set with this control The range is from 25 dB to 15 dB in steps of 1 dB Preset is to 20 dB Silenc...

Страница 11: ...t the status of the unit Input 1 and Input 2 This will show the status of the input It can show SILENCE The input signal has been lost OK The module is receiving a valid input signal Mode Shows whethe...

Страница 12: ...to the right of the item Any of the items may be selected from the list ROLLCALL LOG FIELDS Where Applicable Log Field Log Value Description INPUT_1_STATE OK WARN Silence Status of the input signal IN...

Страница 13: ...his item allows the address of the selected destination unit to be set To change the address type the new destination in the text area and then select return Preset returns to the default destination...

Страница 14: ...rack destination not in use String A string value is always being sent Number A number value is always being sent No The message is not being sent Yes The message is being sent Internal Inconsistent b...

Страница 15: ...o LCD windows Operational details for the remote control panel can be found in the Modular System Operator s Manual Information Window The Information window has four lines of text indicating the curr...

Страница 16: ...Index RollTrack Command RollTrack Command 0 Clear Preset OK RollTrack Sending Status RollTrack Sending Status YES OK RollTrack Address RollTrack Address 0 Clear Preset OK Unit Software Version Serial...

Страница 17: ...more information MAIN MENU IQADA01 MENU Setup RollTrack Logging Setup This allows various functions to be setup Setup Setup Gain 1 Gain 2 Silence Level Silence Detect Time Unit Gain 1 and Gain 2 When...

Страница 18: ...t Selecting this item sets all adjustment functions that include a preset facility to their preset values Note that this is a momentary action Restart This will reboot the unit simulating a power down...

Страница 19: ...ng an item in this menu the status of the item will be shown in the display window Status INPUT_2_TYPE INPUT_2_IDENT INPUT1 INPUT_1_TYPE INPUT_1_IDENT INPUT2 Display Window Logging Status Items Loggin...

Страница 20: ...all RollTrack items will be disabled RollTrack Address This item allows the address of the selected destination unit to be set RollTrack Address RollTrack Address 0 Clear Preset OK To compile edit th...

Страница 21: ...This may show String A string value is always being sent Number A number value is always being sent No The message is not being sent Yes The message is being sent Internal Inconsistent behavior pleas...

Страница 22: ...IQADA01 SECTION N34 IQADA01OPS 19 04 2007 www snellwilcox com Version 1 Issue 1 N37 22 Manual Revision Record Date Version No Issue No Change Comments 18 Apr 07 1 1 First Issue released...