SNC LYTE LYNX P30112 Скачать руководство пользователя страница 3

 

 

 
 

 

1. 0

 

   PRODUCT SCOPE 

This document  describes t he t echnical  specif icat ions,  t echnical  requirement s and inst all at ion 
inst ruct ions f or t he P30112 SNC Lyt e Lynx® 6-Sl ot  Card Shel f .  It  provides an underst anding of  
t he basic f unct ions and f eat ures avail abl e wit h t his product .  

 

  2. 0       PRODUCT OVERVIEW 

 

2. 1

 

Int ended Uses  
The 6-sl ot  Card Shel f  provides an isol at ed int erf ace f or voice (POTS),  anal og dat a and 
digit al  circuit s,  depending on t he isol at ion cards t hat  are insert ed int o t he Card Shel f .   
The primary f unct ion of  t he Card Shel f  is t o provide a convenient  connect ion l ocat ion 
or housing in which isol at ion cards can be insert ed “ t ransparent l y”  int o t he circuit .   
This product  present s a very smal l  f oot print ,  making it  ideal  f or inst all at ions where 
space is at  a premium and onl y f our or six circuit s are required.  

 

Lyt e Lynx® syst ems are int ended f or use at  power subst at ions and simil ar locat ions 
where high vol t age isol at ion is required on t he incoming copper t el ephone pairs t o 
prot ect  t he t el co net work f rom harm and t o provide a personnel  saf et y barrier against  
vol t ages.  This specif ical ly incl udes prot ect ion f rom l ongit udinal  vol t age surges and 
Ground Pot ent ial  Rise (GPR) t hat  may occur during power syst em f aul t s.  

 

2. 2 

Syst em Requirement s 
Print ed circuit  boards designed f or inst al l at ion in t he SNC Lyt e Lynx® 12-Slot ,  6-sl ot  
and 3-Slot  Card Shelves or Tel el ine Isol at or* 8-Sl ot  Card Shel f  may be used.  A 24VDC,  
48VDC,  130VDC or 120VAC power source f rom t he subst at ion is required whenever 
f iber opt ic or ot her act ive el ect ronic PC isol at ion cards are t o be used.  

 

2. 3 

Part s List  
QTY 

 

Descript ion 

2      

 

5/ 16”  X 1 1/ 2”  Lag Bol t s 

   

 

18 pin t erminal  blocks marked RM1,  RM2,  RM3 

 

¾”  inch mal e adapt er f or (CO) remot e side 

 

18 pin t erminal  blocks marked ST1,  ST2,  ST3 

 

1/ 2”  inch mal e st rain rel ief  f or st at ion side 

             1                     6 Foot  A/ C Power Cord 
             1 

 

Descript ion/ Inst all at ion Inst ruct ion Manual  T0395 

 

2. 4

 

Physical  Charact erist ics 

 

2. 4. 1  Mechanical  Conf igurat ion  
The P30112 Card Shel f  is const ruct ed of  a high diel ect ric mat erial  t hat  meet s 
Underwrit ers Laborat ories St andard 94V-0 f l ammabil it y t est .  

 

2. 4. 2  Environment al  Requirement s 
The Lyt e Lynx® syst em is designed f or an indoor environment  and is operabl e in 
t emperat ures ranging f rom –40

฀C to 100฀C (

–40

฀F to 212฀F) under humidity conditions 

f rom 0–99 percent .  (Requirement s f or individual  cards may vary. ) 

 

* Teleline Isolat or is a t rademark of  Posit ron Indust ries,  Inc. 
 

 
 
 
Page 2

 

Содержание LYTE LYNX P30112

Страница 1: ...6 Slot Card Shelf Description Installation P30112 Printed in USA 09 11 TO395 Rev E...

Страница 2: ...1 Station Side Upper Backplane 5 5 2 Station Side Pair Designations 5 5 3 Station Power Ground Connections 6 Figure 2 Station Connectors 6 Figure 3 Connecting 24V External Power Supply 8 Figure 4 Conn...

Страница 3: ...protection from longitudinal voltage surges and Ground Potential Rise GPR that may occur during power system faults 2 2 System Requirements Printed circuit boards designed for installation in the SNC...

Страница 4: ...ber optic isolation cards requires a supply of 24VDC or 48VDC power to operate Floated 48VDC or 130VDC battery and 120VAC power is commonly available at most power substations Various Lyte Lynx intern...

Страница 5: ...ide entrance of card shelf c Strip 1 4 inch from the end of each wire c Secure the wire pairs to the appropriate 18 pin terminal blocks marked ST1 ST2 and ST3 by tightening the screws with a small 1 8...

Страница 6: ...the backplane j acks and assigned a numeric designation i e T1 R1 etc The second pair is connected to the right side of the backplane j acks and is assigned an alpha designation i e TA RA etc See Tabl...

Страница 7: ...RED BLU TC 6 BLU RED RC ST3 51 4 ST3 50 RED ORN T4 7 ORN RED R4 ST3 49 4 ST3 48 RED GRN TD 8 GRN RED RD ST3 47 5 ST3 46 RED BRN T5 9 BRN RED R5 ST3 45 5 ST3 44 RED SLT TE 10 SLT RED RE ST3 43 6 ST3 42...

Страница 8: ...d from the factory with this input terminal wired as primary power 3 BAT Input The third item from the left is a screw terminal block BAT for connecting DC Input Floating Battery 130VDC or 48VDC Only...

Страница 9: ...f as GROUNDED 48VDC A separate wire can be brought into the card shelf and connected directly to the ST1 2 GND and ST2 20 48V terminal block positions The LED indicator j umper J28 must be set to 48V...

Страница 10: ...or power configurations Table 3 Primary Input Voltage Secondary Input Voltage Output Voltage Power Supply Set S5 to Pri Pwr Power Supply Set S5 to Sec Pwr 120 VAC 130 VDC 24 VDC P30114 P30114 48 VDC 2...

Страница 11: ...Side SLOT CONNECTOR COLOR TIP PAIR COLOR RING CONNECTOR J1 RM1 15 WHITE T1 1 BLUE R1 RM1 16 J1 RM1 13 WHITE TA 2 ORANGE RA RM1 14 J2 RM1 11 WHITE T2 3 GREEN R2 RM1 12 J2 RM1 9 WHITE TB 4 BROWN RB RM1...

Страница 12: ...lation equipment shelf and cards and the dedicated entrance cable The 5 kV gap coordinates drainage of surge voltage difference between the dedicated cable pairs and the shield should the power type s...

Страница 13: ...ROUBLE SHOOTING A test card P31102 is recommended for checking correct wiring and correct powering voltages 7 1 LED Not Lit No supply voltage Check with P31102 test card Fuse on AC line receptacle or...

Страница 14: ...GND J1 RM3 RM1 RM2 CTE CTE J3 NOT USED REM GND REM GND T3 R3 J2 REM GND RC TC J3 J4 NOT USED R4 CTE T4 REM GND RD TD CTE J4 J6 J5 REM GND SW1 CTE CTE J6 NOT USED T6 R6 RF TF REM GND R5 CTE T5 REM GND...