background image

pg.8

WATTBOX™ 400 SERIES Installation and Users Manual

SPECIFICATIONS 

 

WB-400-8 

WB-400-CE-10 

WB-400-VCE-12 

AC Power

 

Line Voltage 

120V, 60Hz 

120V, 60Hz 

120V, 60Hz 

AC Input Connection 

IEC C-14 

IEC C-14 

IEC C-14 

Power Cord Length 

6 Feet 

6 Feet 

6 Feet 

Circuit Breaker Rating 

15A 

15A 

15A 

UL Current Rating 

12A 

12A 

12A 

Voltage Protection Rating 
(UL 1449 3rd Edition) 

500V 

500V 

500V 

Joule Rating 

3240 Joules 

3240 Joules 

4320 Joules 

Surge Component 

Ceramic Encased MOV 

Ceramic Encased MOV 

Ceramic Encased MOV 

Protection Modes 

L-N, L-G, N-G 

L-N, L-G, N-G 

L-N, L-G, N-G 

Peak Impulse Current 

72,000A 

72,000A 

96,000A 

Disconnect Circuitry 

Yes 

Yes 

Yes 

Thermal Fuse 

Yes 

Yes 

Yes 

Outlets 

 

 

 

Type 

NEMA 5-15 

NEMA 5-15 

NEMA 5-15 

Numer of Outlets 

10 

12 

Switched 

All 

All 

All 

EMI / RFI Noise Filtration

 

All Outlets 

53 dB, 300KHz to 50 MHz 

53 dB, 300 kHz to 50 MHz 

53 dB, 300 kHz to 50 MHz 

Cable / Satellite Circuit 

 

 

 

Connections 

 

Gold Plated "F" Connector  

Gold Plated "F" Connector  

Surge Component 

 

Gas Tube 

Gas Tube 

Cliping Voltage 

 

600V 

600V 

Frequency Range 

 

0MHz - 3.0 GHz 

0MHz - 3.0 GHz 

Insertion Loss 

 

< 0.5 dB 

< 0.5 dB 

Sheilded 

 

Yes 

Yes 

Bi-directional 

 

Yes 

Yes 

Phone / LAN Circuit

 

Jacks 

 

RJ45 

RJ45 

Accepts 

 

RJ11 & RJ45 

RJ11 & RJ45 

Surge Component 

 

Sidactor & MOV 

Sidactor & MOV 

Cliping Voltage 

 

RJ11:400V; RJ45:250V 

RJ11:400V; RJ45:250V 

Wires Protected 

 

8 Wires 

8 Wires 

UL Certifications

 

UL 60950-1, UL 1449, UL 
498, UL 1283  

UL 60950-1, UL 1449, UL 
498, UL 497A/B, UL 1283  

UL 60950-1, UL 1449, UL 
498, UL 497A/B, UL 1283  

Dimensions 

3.47" H x 17.02" W x 2.13" D

 

3.47" H x 17.02" W x 2.13" D 

3.47" H x 17.02" W x 2.13" D 

Connected Equipment 
Warranty 

$50,000 

$50,000 

$50,000 

 

Содержание WattBox WB-400-8

Страница 1: ...ned for ease of installation Secondary Protection Protected 3 GHz signal coax satellite connections plus Ethernet Telephone connections Flexible Mounting Wattbox flexible mounting options allows verti...

Страница 2: ...ons for Ethernet Telephone 6 Safe voltage switch 7 Detachable power cord outlet with locking clip 8 15 Amp resettable circuit breaker Disables Safe Voltage feature 9 AC Power switch 10 Hook Loop Strap...

Страница 3: ...tlet with locking clip 6 15 Amp resettable circuit breaker 7 AC Power switch 8 Hook Loop Strap Lockdown See Securing Power Adapters on Pg 5 9 Outlets 1 10 EMI RFI Filtered 1 Surge Protection LED indic...

Страница 4: ...r a particular installation Attach the brackets to the Wattbox in the position you desire Install the Wattbox using supplied hardware Small Bracket Mounting 0 0 Screw Position 90 0 Screw Position 0 0...

Страница 5: ...x If the location does not allow for this use a wall molly or anchor with the appropriate weight rating for the Wattbox 3 Level the template and mark the wall with the screw locations 4 Secure the Wat...

Страница 6: ...ounded This protects against voltage surges and static charges Do not place any antenna near overhead power lines or any other power circuit Do not touch any power line or power circuit Doing so may c...

Страница 7: ...one or more components to another Wattbox Too much current may be drawing through one Wattbox Component is not receiving power The component is plugged into a switched outlet and the Wattbox has not...

Страница 8: ...A 5 15 Numer of Outlets 8 10 12 Switched All All All EMI RFI Noise Filtration All Outlets 53 dB 300KHz to 50 MHz 53 dB 300 kHz to 50 MHz 53 dB 300 kHz to 50 MHz Cable Satellite Circuit Connections Gol...

Страница 9: ...ecifications relative to its surge protection capability and under all of the circumstances failed to protect your connected equipment THIS POLICY IS SUBJECT TO THE CONDITIONS BELOW 1 PROOF OF PURCHAS...

Страница 10: ...tic charges periodic checkups routine maintenance loss of use of the product costs or expenses arising out of reprogramming or loss of programming and or data shipping charges or fees service calls lo...

Страница 11: ...WATTBOX 400 SERIES Installation and Users Manual pg 11 2012 Wattbox CONTACTING TECHNICAL SUPPORT Phone 866 838 5052 Email Techsupport snapav com...

Страница 12: ...120302 1033 2012 Wattbox...

Отзывы: