4) 

Overdue Network Check-in

(A properly configured and enabled networked eLock is 

required to make use of this feature)

Overdue Network Check-in 

can be programmed to send an 

alert(s) via LockView’s Remote Alert Messaging if the eLock 

is 

X

 minutes past the programmed scheduled check in 

time. The overdue time is programmable in LockView in one 

minute increments. The Overdue Network Check-in alert will 

be triggered if this time expires before the eLock checks-in 

to the network.

Note: There is no audible alarm that can be triggered at the 

eLock; however, 

NETWORK TEST

  can be used to determine 

Wi-Fi strength and quality.

(See 

LockView Manual 

for 

NOTIFIER 

explanation)

200/300 Series 

VTC eLock — Manual Programming 

continued

q

 

Add, edit, view and delete users / supervisors 

and their credentials

q

 

Add, edit and delete VTC eLocks

®

q

 

Assign access rights between users / supervisors 

and VTC eLocks

®

 in the database

q

 

USB or network connection

*

q

 

Download, view, save, print, archive and delete 

audit trails

q

 

Dual credential access available

q

 

Set real time clock

q

 

Time based access restrictions

q

 

Create user groups

q

 

Windows

TM

 based

q

 

Set up Escalating Notification System

*

q

 

View Compliance Dashboard

*

LockView

®

 software

LockView is a Registered Trademark of CompX International. Windows is a trademark of the Microsoft Corporation. Specifications may vary based on user application.

*  requires network eLock

Содержание Level 5 VTC eLock 200 Series

Страница 1: ...worked and stand alone eLocks please see the Help section in LockView NTC VTC Software v4 1 Dot matrix LCD 2 Network button blue LED 3 UP button 4 NEXT SELECT button 5 BACK CANCEL button 6 MENU button 7 DOWN button 8 Button 9 Button 10 Low battery indicator yellow LED 11 Magstripe reader location if equipped 12 HID Prox or HID iCLASS reader location if equipped 13 ENTER button 14 CLEAR button 15 A...

Страница 2: ...ponents Front view eLock controller Back view VTC eLock controller Battery cable connector Integrated Wi Fi antenna cable included for 300 Series Wi Fi version 200 300 Series VTC eLock Components 9V Battery Jumper Port USB Port for direct connection to LockView software ...

Страница 3: ...not included 2 Wi Fi antenna cable connector or Ethernet connector Wi Fi connector shown 300 Series only 3 Control module battery cable connector 4 2 5 mm AC adapter plug in adapter not included 5 Ground terminal 6 Dual eLatch connector Latch 2 if equipped one latch is included 7 Latch connector Latch 1 one latch is included 8 Battery pack cover 6 AA batteries not included ...

Страница 4: ...ypes To clean the surface of the eLock apply non acid based cleaner to a clean cotton cloth do not spray cleaner directly on the eLock Wipe down keypad and housing taking care around the beeper opening and edges of keypads Wipe excess cleaner off of all surfaces Setting up the eLock Getting Started Out of the Box If the eLock is stand alone 200 Series direct connection via USB to LockView NTC VTC ...

Страница 5: ...Passage Mode has been activated in the eLock To place an eLock into Passage Mode PIN CREDENTIAL 1 Enter a valid PIN between 4 14 digits and press ENTER 2 Press ENTER again HOLD OPEN will flash LOCK IS HELD OPEN will appear in the upper left hand corner of the LCD CARD CREDENTIAL If the eLock is equipped with a card reader HID Prox HID iCLASS or Magstripe 1 Present a valid card within range of the ...

Страница 6: ...low will appear NOTE After 5 minutes of inactivity the eLock will exit SETUP mode 4 Click Yes 5 The below will appear Type in the name of the lock Once a Lock Name has been chosen in LockView it can not be changed Please be sure the name that is chosen is the one that will be used in the future 6 Click Save when done 7 Go to Lock Editor tab in Lock User Editor 8 Left click to highlight the name of...

Страница 7: ...lphabetically by name or showing all supervisors first 6 Press UP DOWN to scroll by line or to scroll by page to highlight credential to be deleted and press NEXT SELECT 7 Press UP and NEXT SELECT to delete DELETED will be displayed when complete 8 Press BACK CANCEL to return to CREDENTIAL MENU VIEW CREDENTIAL Note There are two status levels Supervisor and User Only Supervisors are allowed to VIE...

Страница 8: ...M PM or 24 HOUR M F DATE w MON SUN MM DD YY w MON SUN MMM D YY w MON SUN DD MM YY w MON SUN DD MMM YY w MON SUN YYYY MM DD 1 Press MENU LOGIN PLEASE will be displayed 2 Scan valid credential or enter 4 14 digit PIN and press ENTER 3 Press DOWN button to highlight DISPLAY FORMATS and press NEXT SELECT 4 DISPLAY FORMATTING will be displayed 5 Press UP DOWN buttons to select and buttons to adjust 6 P...

Страница 9: ...ric keypad or buttons to adjust 0 MUTE 6 Press NEXT SELECT when done 7 Press BACK CANCEL to return to main menu Reset Net Schedule A PROPERLY CONFIGURED AND ENABLED NETWORK eLock IS REQUIRED TO MAKE USE OF THIS FEATURE Only Supervisors are allowed to RESET NET SCHED Using RESET NET SCHED the scheduled network check in time can be set 1 Press MENU LOGIN PLEASE will be displayed 2 Scan valid credent...

Страница 10: ... and Hold NEXT SELECT to reset 8 Factory will appear in the upper left hand corner of the eLock LCD Note whenever eLock is in factory mode it is considered unsecured Stand alone Networked eLock Alarm States The eLock has programmable ALARM ALERT STATES 1 Battery Low A properly configured and enabled network eLock is required to make use of this feature Battery Low can be programmed to send an aler...

Страница 11: ... used to determine Wi Fi strength and quality See LockView Manual for NOTIFIER explanation 200 300 Series VTC eLock Manual Programming continued q Add edit view and delete users supervisors and their credentials q Add edit and delete VTC eLocks q Assign access rights between users supervisors and VTC eLocks in the database q USB or network connection q Download view save print archive and delete a...

Страница 12: ... Notes Part 332986000000 Copyright 2012 CompX Security Products Any companies and or products referred to herein are marks or registered trademarks of their respective companies owners and or mark holders ...

Отзывы: