UCS1002 EVB User Manual
SMSC EVB-UCS1002
18
Revision 1.1 (09-30-11)
PRELIMINARY - SMSC CONFIDENTIAL
3.7
Test Points
The EVB provides test points for ground reference and signal access, as listed in
.
Follow these instructions to get the EVB running.
1. Start the UCS100X GUI software. From the Windows Start menu, select Programs > SMSC >
UCS100X.
2. Connect the USB mini connector end of the cable to the EVB and the standard USB connector of
the cable to any available USB port on the PC. The USB Activity LED should light, indicating that
the EVB is getting power.
Table 3.3 Test Points
TEST POINT
SIGNAL FUNCTION MONITORED
1
PWR_EN
2
N/A
3
EM_EN
4
M1
5
M2
6
SMCLK / S0
7
SMDATA / LATCH
8
ALERT#
9
A_DET# / CHRG#
10
DMin
11
DPin
14
DP_out
16
DM_out
SGND1
signal ground
SGND2
signal ground
EGND1
earth ground
EGND2
earth ground
EGND3