![SMSC EMC2102 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/smsc/emc2102/emc2102_user-manual_1306823025.webp)
Fan Speed Control with the EMC2102 Device
SMSC EMC2102
USER MANUAL
Revision 0.2 (09-17-07)
25
5.5.4
Register Change Summary
Table 5.4, "Register Change Summary for Experiment 7"
lists all register value changes from the
default cmf load to accomplish the tests.
Table 5.4 Register Change Summary for Experiment 7
REGISTER
NAME
ADDRESS
DEFAULT
VALUE
NEW
VALUE
COMMENT
Fan
Configuration
52Bh
CBh
4Bh
Disable RPM based fan control algorithm
ABh
C8h - CFh
Demonstrate UPDATE effect
Valid Tach
Count
56H
2010d
5000d
Changed from 2010 RPM to 5000 RPM to show
the effect in closed-loop