Smokemaster F72 Series Скачать руководство пользователя страница 9

9

4700 VDC COLLECTOR

POWER SUPPLY

HIGH VOLTAGE

OUTPUT: 9400 VDC IONIZER

100 Watts Max

INPUT: 120 VAC 50-60 Hz or

             240 VAC 50-60 Hz 
Units are not dual voltage

The line voltage supplied to the F72 air cleaner 
must match the voltage rating stamped on the 
front of the air cleaner. 

 

- CAUTION -  

Only persons qualified to install electrical wiring 
should attempt this procedure.  All wiring must 
comply with applicable codes and ordinances. 
 

A complete internal schematic diagram of the F72 
is shown in Figs. 6 and 7.  Figs. 8 and 9 show 
typical hookups.  Fig. 10 shows typical hookups to 
three phase voltage sources. 
 
 
 
 
 

Figures 6 & 7 – F72 SCHEMATIC

Содержание F72 Series

Страница 1: ...the air at a rate of 1 000 to 12 000 cfm 1 699 to 20 390 m hr in forced air systems x Rated 80 to 99 percent efficient according to the National Bureau of Standards Dust Spot Method using atmospheric...

Страница 2: ...2 TABLE OF CONTENTS PAGE SPECIFICATIONS 3 PLANNING THE INSTALLATION 5 Sizing 5 Location 5 INSTALLATION 7 Wiring 8 SERVICE 11 TROUBLESHOOTING 15 PARTS LIST 17 WARRANTY 20...

Страница 3: ...o the ionizer wires and 4700 Vdc to the collector positive plates The solid state power supply is self regulating so the output voltage remains constant over a wide range of cell dirt loading conditio...

Страница 4: ...45 38 F72B 21 38 F72A 24 31 DUCT OPENING DUCT OPENING 2 06 2 06 21 00 STACKED 53 50 2 44 58 40 1 19 28 00 MINIMUM CLEARANCE FOR CELL REMOVAL AND SERVICE 45 38 F72B 21 38 F72A 24 31 2 44 4 10 Figure 1...

Страница 5: ...usually sized according to the capacity of the air handling system and desired efficiency See Fig 4 LOCATION AND POSITION Because air handling systems vary greatly in arrangement and style factors su...

Страница 6: ...F72 efficiency should be from 85 to 95 percent depending on the application and purpose see Efficiency Chart Fig 4 INDUSTRIAL APPLICATIONS Sizing is determining how many air cleaning units are requir...

Страница 7: ...izing type humidifier is installed upstream mist salts and minerals may decrease the efficiency of the electronic cell and create a need for equipment service When the atomizing type unit must be used...

Страница 8: ...inear 304 8 m INSTALL AIR CLEANER Mount the F72 air cleaner as follows 1 Fabricate and install the necessary vanes and transitions 2 Set the cabinet in position If hanging brackets are used make certa...

Страница 9: ...match the voltage rating stamped on the front of the air cleaner CAUTION Only persons qualified to install electrical wiring should attempt this procedure All wiring must comply with applicable codes...

Страница 10: ...NG BLOWER MOTOR Air cleaner is controlled by a sail switch FIGURE 9 SINGLE SPEED BLOWER MOTOR Air cleaner is controlled by the fan switch and or the fan relay FIGURE 10 F72 AIR CLEANER HOOKUP TO THREE...

Страница 11: ...goggles and gloves Skin contact with either alkaline or acid detergent solution should be avoided REMOVING THE ELECTRONIC CELLS AND PREFILTERS Before the electronic cells and prefilters can be cleaned...

Страница 12: ...state and local pollution control guidelines and requirements Soda ash is one neutralizer 1 Use a polyethylene or Type 316 stainless steel container large enough to hold the electronic cell Other type...

Страница 13: ...pressure water an alkaline detergent should be used if allowed by the high pressure equipment manufacturer DO NOT use an acid detergent except when allowed by the equipment manufacturer 2 Steam Extre...

Страница 14: ...be sure to visually check the electronic cells for bent or damaged collector plates or broken ionizing wires Bent or warped collector plates may be bent back into shape FIGURE 15 REPLACING IONIZING W...

Страница 15: ...igned to speed troubleshooting and to insure the quick detection and proper repair of any malfunction in the electronic air cleaner Most of the troubleshooting steps can be performed by observing the...

Страница 16: ...16 FIGURE 17 EXPLODED VIEW OF THE F72 ELECTRONIC AIR CLEANER...

Страница 17: ...t Filters F72A 2 F72B 4 41113 41113 6 Cabinet Foot 21411 21411 7 Ionizer Wires 38005 38005 8 Indicator Light 10097 10097 9 High Voltage Power Supply Replacement Kit 120V 07081 07081 10 High Voltage Po...

Страница 18: ...______________________________________________________________ ___________________________________________________________________________________ _____________________________________________________...

Страница 19: ...______________________________________________________________ ___________________________________________________________________________________ _____________________________________________________...

Страница 20: ...art shall be for a duration of time no longer than the remaining or unexpired term of the original warranty This warranty does not cover any labor or other service charges incurred by the purchaser Th...

Отзывы: