Installation Continued 

 

7.

 

Replace the front access cover 

8.

 

Please  leave  this  Installation  &  User  Guide  with  the  user  for  future  reference

 

Heat Output Performance  

 

Model 

Heat 

Output 

(kW) 

 Heat 
Output 
(kW) 

 Heat 
Output 
(kW) 

  

High 

Medium 

Low 

  

  

  

  

Caspian 60/03 

3.4 

3.2 

2.9 

Caspian 60/04 

4.6 

4.1 

3.6 

  

  

  

  

Caspian 90/06 

6.7 

6.2 

5.6 

Caspian 90/07 

7.8 

7.0 

6.3 

  

  

  

  

Caspian 120/10 

11.4 

10.4 

8.6 

Caspian 120/11 

12.2 

11.4 

9.5 

Caspian 120/12 

13.1 

12.2 

10.4 

75C inlet water temperature, 18C entering air 
temperature 

 

 
It is recommended that these models are capable of maintaining the calculated heat loss at 

medium

 heat output enabling the boost setting to be used for faster heat up and the low 

speed for maintaining temperature. 
 

Fault Finding 

 
1.

 

Fan does not run on any switch setting. 

a. Check the power supply is switched ON. 
b. Check fuse in the fused spur. 
c. Check the wiring connections at the fused spur. 

 
2.

 

No heat output.  

 

a. Vent any trapped air from the system (with the heating system turned OFF). 

 

b. Check the central heating is switched ON. 

 

c. If a thermostat is fitted ensure it is calling for heat.  

 

d. Balance the central heating system if installed on the same circuit as panel 
radiators and increase the circulating pump speed if required. 
e. Increase the boiler water temperature. 
 

In the event of difficulty please contact our technical help-line on 01245 324560.  It will be 
helpful if you do not disconnect the heater from the central heating system. 

 

Содержание Caspian 60

Страница 1: ...gives many years of service In the event of items missing or visible damage please contact our After Sales Service on 01245 324560 We would be most grateful if you would leave this Installation User G...

Страница 2: ...al connection should be via a 3A fused spur The fused spur must not be directly above the heater but should be accessible after completion of the installation All heaters must be earthed We recommend...

Страница 3: ...the heater pipe work Do not use soldered fittings to the heater pipe work as the heat generated could damage internal wiring and components Note We recommend the use of full flow service valves The v...

Страница 4: ...and attach wires to terminals 6 and 7 as diagram below L N E E N L TO FAN FROM MAINS 1 2 3 4 5 6 7 8 L Commissioning 1 Turn on the electrical supply at the fused spur 2 Turn the thermostat control if...

Страница 5: ...st setting to be used for faster heat up and the low speed for maintaining temperature Fault Finding 1 Fan does not run on any switch setting a Check the power supply is switched ON b Check fuse in th...

Страница 6: ...rs Chelmsford Essex CM3 5UW Tel 01245 324900 After Sales 01245 324560 Fax 01245 324422 E mail info smiths env com Web www smiths env com In light of our policy of continuous development Smith s Enviro...

Страница 7: ...and we would be grateful if you complete and return the Guarantee Registration Card to us as soon as possible This will ensure that should you require assistance we can help you quickly and efficient...

Страница 8: ...mperature Set the heat output switch to medium output setting Providing the water temperature in the central heating system is more than 42 C and the thermostat if fitted is calling for heat the produ...

Отзывы: