The Smithco Commercial Products Two-Year Limited Warranty

Smithco, Inc.  (Smithco) warrants your 2007 or newer Smithco Commercial Product (“Product”) purchased
after January 1, 2007, to be free from defects in materials or workmanship for the period of time listed below.
Where a warrantable condition exists, Smithco will repair the Product at no cost to you including diagnosis,
labor (at the Smithco standard labor rate, subject to the Smithco flat rate schedule), and parts.

Warranty Duration is:

(1) Two years, 1500 operational hours* from the date of delivery to the original purchaser or three years

from the date of original manufacturer of the product, whichever occurs first. (*Products equipped
with hour meter).

(2) Products used in rental situations are covered for 90 days from date of delivery to original user/

renter.

Owner Responsibilities:

As the Product owner, you are responsible for required maintenance and adjustments stated in your Owner’s Manual.
Failure to perform required maintenance and adjustments can be grounds for disallowing a warranty claim.   You are
particularly responsible to train all present and future operators of this product on the safe operation of this
product at your location.

Instructions for Obtaining Warranty Service:

You are responsible for notifying the Authorized Smithco Products Distributor from whom you purchased the Product
as soon as you believe a warrantable condition exists and not later than 30 days from discovery of the condition.

If you need help locating an Authorized Smithco Distributor, or if you have questions regarding your warranty rights or
responsibilities, you may contact us at:

Smithco Product Support Department
200 W Poplar  PO Box 487

Cameron, Wisconsin 54822

Telephone:  1-800-891-9435

E-Mail: 

[email protected]

Maintenance Parts:

Parts scheduled for replacement as required maintenance (“Maintenance Parts”), are warranted for the period of time
up to the scheduled replacement time for that part.

Items/Conditions Not Covered:

Not all product failures or malfunctions that occur during the warranty period are defects in materials or
workman-ship. The items/conditions listed below are not covered by this warranty:

Product failures which result from the use of non-Smithco replacement parts, or from installation and use of
add-on, modified, or unapproved accessories are not cov-ered.

Product failures which result from failure to perform required maintenance and/or adjustments are not cov-

ered.

Product failures that result from operating the Product in an abusive, negligent or reckless manner are not
covered.

This warranty does not apply to parts subject to con-sumption through use, unless found to be defective.
Examples of parts which are consumed, or used up, during normal Product operation include, but are not
limited to: blades, tines, teeth, scarifiers, rakes, plates, wear plates, castor wheels, tires, batteries, filters, belts,

nozzles, etc.

This warranty does not apply to failures caused by out-side influence. Items considered to be outside influ-
ence include, but are not limited to, weather, storage practices, contamination, use of unapproved coolants,
lubricants, additives, or chemicals, etc.

Содержание Spray Star 2005

Страница 1: ...ay Star 2005 2006 2005D 2006D SharpShooter Rate Sync w Envizo Pro II with 18 and 20 Booms July 2016 Operator s Product Support Hwy SS Poplar Ave Cameron WI 54822 1 800 891 9435 productsupport smithco...

Страница 2: ...g Instructions 14 16 Envizio Pro II Do s and Don ts 16 SharpShooter RateSync Console Features 17 Initial Set Up of Envizio Pro II 18 21 SharpShooter Rate Sync Control 22 23 Spray Operation 24 25 Re Ca...

Страница 3: ...ordering parts The serial number plate on the Spray Star 2000 is located on the right middle main frame Refer to engine manual for placement of engine serial number Refer to engine manual for placemen...

Страница 4: ...elease Hydraulic Oil Level Choke Open Choke Closed Hand Throttle Hour Meter Hour Meter Fuse Glow Plug Glow Plug Off Glow Plug On RPM Gasoline Diesel Water Temperature Temperature Light Engine Oil Engi...

Страница 5: ...MBOLS No Smoking Moving Parts Manual Operation Pinch Point Step Hot Surface Hydraulic Fluid Penetration Lift Arm Tractor Engage Disengage PTO Ground Speed Fast Slow H High L Low F Forward R Reverse N...

Страница 6: ...azardous situa tion that if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situations typically for machine components which for functional pu...

Страница 7: ...e available from your autho rized distributor This is a list of decals located on the Spray Star 2000 Part number description and location will help in reorder ing a decals A 15 463 Decal Spray Pump 1...

Страница 8: ...all drives and set park brake before starting the engine 12 Never use your hands to search for oil leaks Hydraulic fluid under pressure can penetrate the skin and cause serious injury 13 This machine...

Страница 9: ...Check hoses for weak or worn condition before each use Make certain that all connections are tight and secure 11 Do not operate unit with leaks frayed kinked hoses or tubing Repair or replace immediat...

Страница 10: ...riable 0 10 m p h 0 16 kph BATTERY Automotive type 24F 12 volt BCI Group Size 24 Cold Cranking Amps 900 minimum Ground Terminal Polarity Negative Maximum Length 10 25 26 cm Maximum Width 6 88 17 cm Ma...

Страница 11: ...12 NHS Multi Trac 18 psi 1 3 bar SPEED Infinitely Variable 0 10 m p h 0 16 kph BATTERY Automotive type 24F 12 volt BCI Group Size 24 Cold CrankingAmps 900 minimum Ground Terminal Polarity Negative Max...

Страница 12: ...ILL 4 Fill fuel tank located on the left side with Unleaded 87 Octane gasoline minimum Fuel is flammable caution must be used when storing or handling it Do not fill fuel tank while engine is running...

Страница 13: ...11 Introduction PARTS MANUALS AVAILABLE ONLINE AT smithco com NOTES...

Страница 14: ...top and off by pushing on the bottom G Buzzer The buzzer sounds if the pump is running dry H Ground Speed Cruise Control This rocker switch initiates cruise control by pushing on the top and turning i...

Страница 15: ...ruise R Master Boom Switch located on the left floorboard is used to override the master switch on the computer console of the spray systems By pushing down it will turn on off the booms For the 440 S...

Страница 16: ...nds to inspect for leaks 6 Check the hydraulic fluid level The hydraulic fluid tank is located on the left side of the machine The fluid level should be 2 2 5 6 4 cm from the top of the tank when cold...

Страница 17: ...the battery When charging or working near battery always shield your eyes and always pro vide proper ventilation Battery cable should be disconnected before using Fast Charge Charge battery at 15 amp...

Страница 18: ...7 6 28 8 5 32 4 2 15 9 50 3 4 12 2 46 2 5 32 5 5 20 8 100 6 9 17 5 66 2 3 16 3 6 13 6 25 1 7 9 1 34 4 3 16 5 6 21 2 50 33 4 14 3 54 1 3 16 7 9 29 9 100 6 9 18 7 70 8 You can change orifice disc sizes...

Страница 19: ...P To Begin a Job Create a Spray Zone Turn Sharpshooter w RateSync On Press Auto Manual button to Auto PSI is preset Use arrow buttons to increase decrease POWER Home Screen Switch Pro AccuBoom Switche...

Страница 20: ...re you can Start a New Job 3 New Job Menu 4 Start a New Job Screen Insure Arrow on Tractor is Forward Touch the Yellow New Job Box Touch Icon to Correct if Needed This will bring up the Keyboard Scree...

Страница 21: ...Name the New Field Boundary Map it s best to use the same name as the New Job file Touch the Green Check Circle This will return you to the Job As Applied Screen 10 Creating a Field Boundary Drive to...

Страница 22: ...dary Tools on Screen 14 Drive the Outline of the Area You will see the Yellow Line that will be the boundary of the Field Boundary located at your selection point Press the Black Pause Box at any time...

Страница 23: ...m INITIALSETUP 16 Press the Green Menu Box then the Green Check Box 17 The Spray No Spray Boundary Line will then be represented in Blue and Areas with Application Previously Applied will be Represent...

Страница 24: ...ent tips Menu Button The menu button is used to enter and exit the menu list Press menu button to enter the menu list pages use the increase decrease buttons to navigate the menu list highlighting the...

Страница 25: ...SharpShooter with Rate Sync system operation Actual pressure effective tip size and duty cycle are displayed in the Manual mode Actual pressure target pressure and duty cycle appear in the AUTO mode A...

Страница 26: ...computer must be on for the master boom control switch to work For the 440 System the Master Switch on the computer must be off for the master boom control switch to work Review the capacity of nozzle...

Страница 27: ...hose or spray boom with nozzles removed until empty 3 Remove drain coupling again and rinse tank interior thoroughly 4 Rinse exterior of sprayer thoroughly with clean water 5 Remove bowl from sprayer...

Страница 28: ...have to be applied so that they get into the soil below the plant leaves This is called soil appli cation In order to do this they are best applied with a large volume of water They are often then wat...

Страница 29: ...es Plunger blockage Plunger stuck Plunger blockage results when larger debris catches between the orifice and plunger seal This is the smallest flow passage within the nozzle valve Stuck plungers resu...

Страница 30: ...the plunger for wear or damage Replace plunger if worn or damaged Remove debris from nozzle components by washing components with clean water After extended use the soft plunger seal Item 1 will wear...

Страница 31: ...39 3 7 325 6 204 0 626535627 37 59213759 38 3 8 334 4 204 0 610047847 36 60287081 37 3 9 343 2 204 0 594405594 35 66433566 36 4 352 204 0 579545455 34 77272727 35 4 1 360 8 204 0 5654102 33 92461197 3...

Страница 32: ...30 Reference...

Страница 33: ...gteljes tm nyszint Livello di potenza sonora misurato Izm r tais ska as jaudas l menis I matuotas garso stiprumo lygis Livell tal Qawwa tal oss Iggarantit Moc akustyczna mierzona N vel sonoro medido N...

Страница 34: ...n valmistajan valtuutus vakuutuksen laadintaan jolla on hallussaan teknisetasiakirjat joka on valtuutettu laatimaan tekniset asiakirjat ja joka on sijoittautunut yhteis n Signature de la personne habi...

Страница 35: ...33 Reference NOTES...

Страница 36: ...esel Spray Star 2000 REPLACEMENTBELTS 30 137 Spray Pump V Belt SEALKITS 15 301 Power Steering Orbital Motor 15 301 01 Seal Kit 15 839 Hydraulic Cylinder 14 531 Seal Kit 43 116 Wheel Motors 14 080 Seal...

Страница 37: ...you need help locating an Authorized Smithco Distributor or if you have questions regarding your warranty rights or responsibilities you may contact us at Smithco Product Support Department 200 W Pop...

Страница 38: ...ty gives you specific legal rights and you may also have other rights which vary from state to state THERE ARE NO OTHER EXPRESS WARRANTIES OTHER THAN THOSE SET FORTH ABOVE ALL IMPLIED WARRANTIES OF ME...

Отзывы: