6.3 PWR connector
The connector used to power the POSYC 340X, has spring contacts to facilitate wiring of individual cables.
Connector type: Phoenix Contact FK-MCP 1,5/2-STF-3,81 (1851232) * **
Order code: KF101074
Features
Conductors cross section
Connection in accordance with
EN-VDE
Solid min.
0,14 mm²
Rated voltage
320V
Solid max.
1,5 mm²
Rated current
8A
Stranded min.
0,14 mm²
Stranded max.
1,5 mm²
Insulating material
PA
Stranded, with ferrule without plastic
sleeve min.
0,25 mm²
Inflammability class according to
UL 94
V0
Stranded, with ferrule without plastic
sleeve max.
1,5 mm²
Stripping length
9 mm
Stranded, with ferrule with plastic sleeve
min.
0,25 mm²
Screwdriver to be used for open-
ing the connections
0,6 x 3,5 mm
Stranded, with ferrule with plastic sleeve
max.
0,5 mm²
*= Use only 75°C cables
**= Use only copper conductors
Supply 24VDC
Pin
Signal
1
VM (24 VDC)
2
GND
1
2