Smitec POSYC 3401 Скачать руководство пользователя страница 1

Industrial computers POSYC 3401/3402 

Installation, use and maintenance manual - EN 

Ver. 1.03

Smitec S.p.A., viale Vittorio Veneto 4, 24016 San Pellegrino Terme (BG), Italy, www.smitec.it

Installation, use and maintenance manual

 INDUSTRIAL COMPUTERS

 POSYC 3401/3402

 

BEFORE STARTING UP THE INDUSTRIAL COMPUTERS POSYC 3401/3402, CARE-

FULLY READ THIS MANUAL AND FOLLOW ALL INSTRUCTIONS, IN ORDER TO EN-

SURE MAXIMUM SAFETY

The technical data and the drawings in this manual might have been modified later; always

refer to the latest version.

Содержание POSYC 3401

Страница 1: ...ly www smitec it Installation use and maintenance manual INDUSTRIAL COMPUTERS POSYC 3401 3402 BEFORE STARTING UP THE INDUSTRIAL COMPUTERS POSYC 3401 3402 CARE FULLY READ THIS MANUAL AND FOLLOW ALL INS...

Страница 2: ...view 10 5 3 1 3 Rear view recommended panel cut 11 5 4 Hardware features 12 5 4 1 Basic hardware 12 5 4 1 1 POSYC 3401 12 5 4 1 2 POSYC 3402 12 5 5 Order codes 13 5 6 Accessories 13 6 Connections and...

Страница 3: ...sed to the following professionals The present instructions must be made available to all the above individuals User User is a person a company or an institution that buys the equipment and uses it fo...

Страница 4: ...dopted DO NOT USE THE EQUIPMENT NOR MAKE ANY INTERVENTION BEFORE INTE GRALLY READING AND UNDERSTANDING THIS MANUAL IN PARTICULAR ADOPT ALL SAFETY PRECAUTIONS AND PRESCRIPTIONS INDICATED IN THIS MANUAL...

Страница 5: ...y prescriptions aim at establishing a series of behaviors and obligations to be complied with while performing the activities described later on in this manual These prescriptions constitute the presc...

Страница 6: ...and the drawings in this manual might have been modified later always refer to the latest version All upgrades can be requested to SMITEC S p A directly Make sure that the personnel is qualified and a...

Страница 7: ...e quire resistance to external agents such as dust humidity water oils etc which would be harmful for standard devices Since it is sufficient to exert a slight pressure with a finger on its surface to...

Страница 8: ...ving or updating the product technologically SMITEC S p A reserves the right to change the technical features of the POSYC computer without notice Operating temperature 0 50 C when operational Storage...

Страница 9: ...dimensions 5 3 1 1 Front view The computers Posyc 3401 3402 need to be fixed on a stable and rigid panel provided with 4xM3 metal thread ed hole min 1 5mm deep Use 4xM3x10mm Fe Zn not countersunk head...

Страница 10: ...Industrial computers POSYC 3401 3402 Installation use and maintenance manual EN Ver 1 03 10 5 3 1 2 Side view...

Страница 11: ...Industrial computers POSYC 3401 3402 Installation use and maintenance manual EN Ver 1 03 11 5 3 1 3 Rear view recommended panel cut...

Страница 12: ...either for production continuity nor for functionality Processor ARM Cortex A9 i MX6SX 1GHz Memory 1GB DDR3L Display 7 color LED TFT 800x480 16M with integrated touch panel Touch screen sensor 4 resis...

Страница 13: ...ode Model Description KZ010501 3401 Hardware base PC with I O 2 Ethernet FLEXIO bus isolated KZ010528 3402 Hardware base PC without I O 1 Ethernet FLXIO bus not isolated KZ010573 3402 AUDION UL Hardwa...

Страница 14: ...SYC POSYC 3401 POSYC 3402 Name Function PWR 24 VDC power supply connection FE Earth protection connection ETH 1 Ethernet communication port 1 ETH 2 Ethernet communication port 2 only for POSYC 3401 I...

Страница 15: ...r micro SD card USB AB AB type USB micro port for SMITEC internal use only RESET Reset button USB 1 Port 1 USB 2 0 USB 2 Port 2 USB 2 0 R Red LED indication of operating status of the device depends o...

Страница 16: ...min 0 14 mm Rated voltage 320V Solid max 1 5 mm Rated current 8A Stranded min 0 14 mm Stranded max 1 5 mm Insulating material PA Stranded with ferrule without plastic sleeve min 0 25 mm Inflammability...

Страница 17: ...a Pay the utmost attention to prevent such phenomena complying with the provisions of the law in order to avoid damage to the device Utilisez un c ble de section appropri e dimensionn correctement en...

Страница 18: ...J45 Ethernet connectors The Ethernet port has two LEDs The first one in green color marked with the letter L indicates if the door is connected The second orange marked by the letter A indicates the s...

Страница 19: ...ade via the RJ45 connectors the following illustration shows the pinout of one of the connectors and the behavior of the LED S This fieldbus requires a minimum CAT 5 type shielded cable headed with RJ...

Страница 20: ...ss section Connection in accordance with EN VDE Solid min 0 2 mm Rated voltage 160V Solid max 1 5 mm Rated current 8A Stranded min 0 2 mm Stranded max 1 5 mm Insulating material PA Stranded with ferru...

Страница 21: ...EN Ver 1 03 21 1 13 2 14 I O port Pin Signal 1 FE 2 FE 3 VI 24V inputs power supply 4 VO 24V outputs power supply 5 GI GND 6 GO GND 7 IO5 Input 5 8 IO1 Input output 1 9 IO6 Input 6 10 IO2 Input output...

Страница 22: ...tallation of the POSYC 340X computer falls and violent shocks must be avoided which could compromise the smooth operation Avoid touching the input output connectors on the computer panel directly unle...

Страница 23: ...ge is within the parameters specified The connection of POSYC to peripherals is simplified by the use of standard computer connectors this means that all standard peripherals for personal computers ca...

Страница 24: ...to com mand the operating system pointer to move below the area where the pressure has been exerted Depending on the software settings the touch screen simulates dragging clicking double clicking and...

Страница 25: ...allows a quick replacement both in case of failure and off line software update CAUTION ATTENTION To avoid computer failures and or data loss to micro SD card replacement of the same must be done onl...

Страница 26: ...If necessary the front of the device keyboard and viewing window can be cleaned with a very soft cleaning cloth recommended in microfibre dampened with water or cleaning solution for display 9 2 Repl...

Страница 27: ...25 C CFast card 25 Cleaning 26 Current consumption 8 D Display 12 E Ethernet 12 18 F Fixing 9 FLXIO 7 12 19 H HMI 7 I I O 7 12 20 L LEDs 14 M Maximum altitude 8 Memory 12 Micro SD card 12 P Panel cut...