3.0 TECHNICAL DATA 

 

 

 

 

 

Mild Steel, Powder Coated 

Code 

3081 

3082 

3083 

3084 

3085 

3086 

Size 

User Weight (kg) 

150 

150 

150 

150 

150 

150 

Height Range (mm) 

450-950

2

 

450-950

2

 

450-950

2

 

450-950

2

 

450-950

2

 

450-950

2

 

Table Dimensions 

L Length (mm) 

1200 

1300 

1400 

1500 

1600 

1700 

W Width (mm) 

550 

550 

600 

600 

650 

650 

M Width (mm) 

1010 

1010 

1060 

1060 

1110 

1110 

M Width (mm)

 3

 

875 

875 

925 

925 

975 

975 

Safety Sides 

Y Height (mm) 

300 

300 

300 

300 

300 

300 

Y Height (mm)

3

 

165 

165 

165 

165 

165 

165 

Wall Frame

 

A Width (mm) 

700 

700 

700 

700 

700 

700 

B Depth (mm) 

110 

110 

110 

110 

110 

110 

C Height (mm) 

1150 

1150 

1150 

1150 

1150 

1150 

Storage 

S Width (mm) 

305 

305 

305 

305 

305 

305 

Shipping Weight (kg) 

80 

82 

84 

86 

88 

90 

2

Dependant upon installed height 

3

When fitted with Stowaway safety rails 

Содержание Easi-Lift

Страница 1: ...1 12 Easi Lift INSTRUCTIONS FOR USE Codes 3081 3086...

Страница 2: ...n a room where space is at a premium Its compact design means that it fits well into a wide range of environments IMPORTANT These instructions should be read by all therapists and carers using the equ...

Страница 3: ...Easi Lift 2 2 0 ILLUSTRATION OF YOUR EASI LIFT CHANGING TABLE A Safety side1 B Bed C Wall frame 1 The Easi lift is supplied with either standard safety side or stowaway variant as displayed A B C...

Страница 4: ...Width mm 550 550 600 600 650 650 M Width mm 1010 1010 1060 1060 1110 1110 M Width mm 3 875 875 925 925 975 975 Safety Sides Y Height mm 300 300 300 300 300 300 Y Height mm 3 165 165 165 165 165 165 W...

Страница 5: ...garettes and sources of heat including open fireplaces radiators and heaters Regular maintenance checks and cleaning are essential for the safe use of this equipment see care and maintenance section D...

Страница 6: ...trical power points switches etc which may affect the installation Check there is sufficient room around other facilities e g wash basins toilets etc Remember to take into account the safety rail dime...

Страница 7: ...ift and lay all parts on to the floor Check all components are present and check for damage that may have occurred in transit see illustration below Wall Frame Bench frame with mattress and safety sid...

Страница 8: ...oved and a small amount of Loctite applied to the first 5mm Offer up the bench and insert the two bolts previously prepared but do not over tighten The bolts must not protrude more than approx 1mm Wit...

Страница 9: ...epeat in rapid succession as this will put stress on the motor system and can cause damage through overheating The main front cover can now be refitted and fixed into place by sliding it down behind t...

Страница 10: ...nd hand to release the plunger locking pin which is situated by the right hand hinge shown circled opposite When unlocked use both hands to lower the bed into the horizontal position Before transferri...

Страница 11: ...nd when vertical press firmly to slightly compress the mattress listen for a click which indicates that the plunger locking pin has engaged into the locked position Confirm this by gently pulling the...

Страница 12: ...uthority cleaning guidelines 7 1 MAINTENANCE CHECKS IMPORTANT Regular maintenance checks are required 7 1 1 DAILY CHECKS Check the mattress for signs of damage or wear and tear Keep the upholstery and...

Страница 13: ...red to be Daily use above 7 hours duration Weekly use above 5 days duration Monthly use above 10 months per year Use by a client who is at 90 to 100 of the maximum weight limit of the product The maxi...

Страница 14: ...G S Smirthwaite Ltd It is the equipment owner s responsibility to maintain their own records of changes to the equipment configuration and to be able to provide such records to subsequent owners to m...

Страница 15: ...to encourage everyone to reuse recycle and recover it As the responsible manufacturer Smirthwaite operate a take back scheme wherein we accept electrical and electronic components returned to our fac...

Страница 16: ...es not apply to accidental damage caused through inappropriate use of the product This guarantee is issued at the discretion of G S Smirthwaite Ltd on RTB Return to Base basis If you have any question...

Страница 17: ...roduct design department at enquiries smirthwaite co uk G S Smirthwaite Ltd reserve the right to change the specification or material without prior notice For catalogues help and further information o...

Страница 18: ...Easi Lift 17 10 0 WARRANTY AFTERSALE 10 1 Product Information Model Size Date of Manufacture Serial Number Final Inspection 10 2 Service inspection record form Date Procedure Service Personnel...

Страница 19: ...Easi Lift 18 Notes...

Страница 20: ...Easi Lift 19 G S Smirthwaite 17 Wentworth Road Heathfield Newton Abbot Devon TQ12 6TL T 44 0 1626 835552 F 44 0 1626 835428 E enquiries smirthwaite co uk www smirthwaite co uk...

Отзывы: