![smev SMEV 8000 SERIES Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/smev/smev-8000-series/smev-8000-series_service-manual_1305154008.webp)
Page 7
Camec Service Guide for Australia and New Zealand
Insufficient water temperatures
Thermostat not seated against tank
Reset thermostat firmly in position
Erratic burner flame or sooting
Low gas pressure
Set inlet pressure at a minimum 11” W.C. with two or more gas appliances running
Poor gas supply
Replace gas supply
Blocked burner orifice
Clean orifice with compressed air - DO NOT enlarge orifice
No spark and no gas
No voltage
Make sure you have the correct power supply - 10.5 VDC minimum
Dirty edge connector on circuit board
Clean edge connector with a soft cloth
Defective thermal cut-off
Replace thermal cut-off
Fails to ignite
Cracked electrode ceramic
Replace spark electrode
Chattering or fluctuating thermostat
Replace thermostat
Insulation on electrode wire cut or damaged
Replace electrode
Ground screw at top of circuit board not tight
Tighten ground screw - if stripped, replace with larger screw
The water tank is enclosed in a styrofoam insulation case. DO NOT REMOVE THIS.
Please read carefully the Atwood Hot Water Service Instructions before lighting.