background image

 

 

- 10 - 

4 FUNCTIONING 

 

4.1 

FIRST START UP 

 

ATTENTION 

 

The first start up of the system must be carried out by the installer who will make sure 
the machine runs properly. 

 

Insert the feed plug in a 230V 50Hz outlet equipped with efficient grounding. Now the 

system is able to work. It advisable to run the run for at least a half an hour before 
drinking it, in order to allow the system to eliminate the substances used to conserve the 

reverse osmosis membrane. 

 

Make sure there are no leaks in the circuit and fasten the antiflooding probe on the 

bottom of the machine. 

 

Close the cover with the screws position the machine in its final destination and push the 
brakes of the whells. 

 

Operate sanitation of equipment as described in section 5.8. 

 
The WO-03  membranes are provided saturated in a maintenance solution. Before taking water, let it run 

for at least 15-30 minutes. 

4.2 NORMAL 

USE 

In order to normally use WO-03  the machine must always be kept on.The machine starts automatically at 
every rising cycle of the dish/wash machine. Every six hours the machine automatically opens the inlet 

solenoid valve, in this way the membranes are washed for 2 minutes. 
To adjust the salinity of the water, acting on the valve for mixing later. 

If high water consumption occurs, the by-pass solenoid valve opens and raw water flous to the outlet. 
 

ATTENTION 

 

Absolutely avoid letting the membranes dry out; this could irreparably compromise its 

functioning. 

 

4.3 INACTIVITY 

 

ATTENTION 

 

It is advisable, each time the machine is inactive for a period over one week, to let the 

water run for at least 10 minutes before using it. 

 

It is advisable to sanitize the system every six months during routine maintenance 

procedures. 
Contact assistance in order to carry out this operation, which must be performed by 

specialized personnel/installation technicians. 

 

 

 

4.4 

ELECTRONIC BOARD OPERATING 

 

4.4.1 Normal functioning 

 

When the card is in normal functioning mode, the name of the reseller is 

displayed. 
 
 

When the faucet is opened, the machine starts to produce permeate water; 

pushing the key ENTER 

, the conductivity is displayed. 

 

SMEG 

uS/cm 

0050 

Содержание WO-03

Страница 1: ...1 WO 03 Reverse osmosis equipment for dish glass washmachines MANUAL use and maintenance SERIAL N __________________ CODE __________________ Note _____________________________________________...

Страница 2: ...USE 10 4 3 INACTIVITY 10 4 4 ELECTRONIC BOARD OPERATING 10 5 ROUTINE MAINTENANCE 13 5 1 MAINTENANCE PERSONNEL QUALIFICATIONS 13 5 2 MAINTENANCE PERSONNEL TASKS 13 5 3 REPLACING FILTER CARTRIDGE 14 5...

Страница 3: ...l as qualified technicians must carefully read the instructions in this manual Users can only carry out the operations indicated in this manual and must not perform any operations reserved for mainten...

Страница 4: ...hase of the dish glass washmachine cycle ATTENTION The water consuption of the dish glass washmachine installed after the WO 03 must respect the maximum performance of the system All components of the...

Страница 5: ...4 DESCRIPTION The machine has on the rear side no 4 hydraulic connections for inlet water permeated water drain and auxiliary permeate outlet On the rear side there is also the electric socket whit f...

Страница 6: ...aps the unwanted concentrated impurities The drainage flow is also used to clean the membrane and is directly connected to the drainage system by plastic brackets The mix valve allows the user to choo...

Страница 7: ...UND Voltage V 230 Frequency Hz 50 Absorbed current A 2 5A Power W 150W Fuse type electronic board F5A Fuse type elettrica connector F4A PERMEATE WATER SPECIFICATIONS Maximum capacity at 15 C l h c a 9...

Страница 8: ...ould cause condensate to form inside which can damage the electronic part Make sure the air vents are never blocked in order to not compromise motor cooling Instructions and representation to follow a...

Страница 9: ...he drain siphon pipe in correspondence with the nut that has just been removed Insert the drainpipe in the nut for about 2 cm and screw the nut on the clamp Fasten the screw nut and install the check...

Страница 10: ...chine starts automatically at every rising cycle of the dish wash machine Every six hours the machine automatically opens the inlet solenoid valve in this way the membranes are washed for 2 minutes To...

Страница 11: ...splays the version of software installed in the card To scroll the next pages press the key the first page displayed enables carryng out the manual flow of the membrane in order to carry out the opera...

Страница 12: ...confirms the zeroing of the counter the card will therefore display Data saved Move to the next page with the key access the selection of the tap type with the key Select the type of tap manual or el...

Страница 13: ...e familiar with this manual and all information concerning safety Sufficient level of general and technical knowledge in order to understand the contents of this manual Knowledge of the main hygienic...

Страница 14: ...eaning the machine do not use corrosive products acids abrasive or steel brushes Do not directly wash the machine with high pressure jets of water 5 3 REPLACING FILTER CARTRIDGE The repleace the prefi...

Страница 15: ...reaches about 3 5 bar Slowly unscrew the calibration nut of pressure switch until the operation of the machine becomes discontinuous Apply the glue sealant to calibration nut Install a T fitting and a...

Страница 16: ...at 36 volumes per 10 liters of permeated water Put 50ml of hydrogen peroxide at 130 volumes per 10 liters of permeated water Connect the water pipes of entry drain and permeated by the machine at the...

Страница 17: ...ic board with reverse procedure 1 2 3 4 5 3 7 2 6 6 6 2 PROTECTION FUSE REPLACEMENT The machine is equipped with two fuses one on the electronic board and one on the power socket 6 2 1 Protection fuse...

Страница 18: ...electronic board with reverse procedure 6 3 PUMP REPLACEMENT Remove the frontal and the mantel of machine Disconnect the piping from the pump Unscrew the screw of the clamp connecting and disassemble...

Страница 19: ...80 S cm2 replace the osmotic membrane as follows Disconnect the tubes from the fittings of the vessel containing the membrane Dismantle the vessel from the machine and unscrew the caps Dismantle the m...

Страница 20: ...Incorrect wiring Check the wiring and the fastening of the cables to the terminals Problem The display shows Alarm Leakage Cause Solution Leakage Open the machine and check carefully all hydraulic cir...

Страница 21: ...Water leakage Check the permeate hydraulic circuit for leakages install a manometer on permeate line and check water pressure on permeate line Problem With faucet opened the machine doesn t start Cau...

Страница 22: ...osos nos lixos minicipais O s mbolo da barra no barril lembra ao utilizador de n o jogar este producto como um lixo municipal n o classificado D Gem Richtlinie 2002 96 EC wird diese Produkt als elektr...