Installation
78
The nozzles not provided are available at Authorised Service Centres.
8
Liquid Gas
G30/31
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
50
65
85
46 + 91
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced capacity (W)
400
500
800
1900
Rated capacity G30 (g/h)
73
131
211
305
Rated capacity G31 (g/h)
71
129
207
300
9
Liquid Gas
G30/31
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
50
62
81
46 + 85
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced capacity (W)
450
550
800
1900
Rated capacity G30 (g/h)
80
131
211
305
Rated capacity G31 (g/h)
79
129
207
300
10
Liquid Gas
G30/31
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
43
58
70
43 + 70
Pre-chamber (printed on nozzle)
(H2)
(M)
(Y)
(H2) + (S1)
Reduced capacity (W)
400
500
850
1900
Rated capacity G30 (g/h)
73
131
211
305
Rated capacity G31 (g/h)
71
129
207
300
11
City Gas G110
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.8
3.8
Nozzle diameter (1/100 mm)
145
185
260
140 + 320
Pre-chamber (printed on nozzle)
(/8)
(/2)
(/3)
-
Reduced capacity (W)
400
500
800
1400
12
City Gas G120
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.8
3.9
Nozzle diameter (1/100 mm)
135
175
240
130 + 290
Pre-chamber (printed on nozzle)
(/8)
(/1)
(/3)
-
Reduced capacity (W)
400
500
800
1400