Instruction for the installer
11
3.4
Burner and nozzle characteristics table (90 cm models)
Burner
Rated
heating
capacity
(kW)
LPG
–
G30/G31
28/37
mbar
Nozzle
diameter
1/100 mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1
50
350
73
71
Semi-rapid
1.8
65
450
131
129
Rapid
3
85
800
218
214
Triple crown
3.2
91
1500
233
229
Oven
1.9
68
800
138
136
Burner
Rated
heating
capacity
(kW)
NATURAL GAS –
G20
20
mbar
Nozzle diameter
1/100 mm
Reduced Flowrate
(W)
Auxiliary
1
72
350
Semi-rapid
1.8
97
450
Rapid
3
115
800
Triple crown (4)
3.5
133
1500
Triple crown (8)
3.5
140
1500
Oven
3.2
130
850
3.5
Arrangement of burners on cooking hob
BURNERS
1.
Auxiliary
2.
Semi-rapid
3.
Rapid (60 X 60)
4.
Triple crown
5.
Large electric hob (1500W)
6.
Small electric hob (1000W)
8.