Instructions for the installer
11.5.2Adjusting the hob burner minimum setting for LPG
In order to adjust the minimum setting with LPG, the screw at the side of the tap rod must be tightened
clockwise all the way.
11.5.3Adjusting the gas oven burner minimum setting
1 Light the oven burner and keep it at the maximum for 10/15 minutes.
2 Then turn the knob to the minimum temperature.
3 Extract the gas tap knob and turn the adjustment screw next to the tap rod
(depending on the model) until the correct minimum flame is achieved.
4 Refit the knob and verify that the burner flame is stable (when turning the
knob rapidly from the maximum to the minimum position the flame must not
go out). This procedure must be carried out while the door is closed.
5 (Only for adjustment different from LPG) Open and close the door, if the flame
goes out the minimum must be increased.
If using LPG, the adjustment screw must be tightened to end of stroke. If using city gas or natural gas,
simply unscrew the adjustment screw by a few turns.
11.6 Burner and nozzle characteristics table
Burner
Rated heating
capacity
(kW)
LPG GAS - G30/G31 28-30/37 mbar
Nozzle
diameter
(1/100 mm)
Reduced
capacity
(W)
Capacity
(g/h G30)
Capacity
(g/h G31)
Auxiliary
1.05
50
400
76
75
Semi-rapid
1.8
65
500
131
129
Rapid
3.0
85
800
218
214
Ultra-rapid
3.5
94
1600
255
250
Oven
2.6
76
900
189
186
Grill
2.4
76
-
175
171
Burner
Rated heating
capacity
(kW)
NATURAL GAS - G20 20 mbar
Nozzle
diameter
(1/100 mm)
Prechamber
(printed on
nozzle)
Reduced capacity
(W)
Auxiliary
1.05
72
(X)
400
Semi-rapid
1.8
97
(Z)
500
Rapid
3.0
115
(Y)
800
Ultra-rapid
3.5
133
(S)
1600
Oven
2.6
120
-
900
Grill
2.4
120
-
-
Содержание SSA60GGX8