7

 

USING THE HOB 

 

   

Before turning on the burners, make sure that the burner rings, caps 

 

and grids have been fitted correctly. 
In the ultrarapid burner, notch 

must be aligned with pin 

B

 

Grid 

(where available) is intended for use with woks (Chinese pans). 

Adapter 

comes only with open grids models and is intended for use 

with small sized vessels.

 

 

   

 

 

 

   

 

 

7.1

 

Ignition of the burners 

 

   

 

 Raised indicators make for easier and clearer reading and use of the 

controls, each knob being connected to its corresponding burner by a 
rib. Setting corresponds to the elongated part of the knob or to the 
marking on it. 
 
(Only where applicable) 
Double-crown burners, controlled by two knobs, feature two ribs, a long 
one corresponding to the small inner burner and a short one to the 
outer burner. 
Double-crown burners comprise an auxiliary and a rapid burner, 
controlled by two different knobs which allow both burners to be used 
at the same time or to select one or the other as required. 

 

   

The device is fit with electronic ignition. Simply press and 
simultaneously turn the knob counter-clockwise on the low point flame 
symbol, until the burner is ignited. 

 

Concerning models with valves, push the knob for approximately 2 
seconds in order to keep the flame burning and to activate the safety 
device. 

 

The burner might go off when the knob is released. In this case repeat 
the aforesaid operation keeping the knob 
pressed for more than 2 seconds. 

 

   

Should the burners go off accidentally in the models with valves, a 

 

safety device will trip after approximately 20 seconds to block the gas 

outlet even if the cock is open.

 

 

 

 

 

Содержание SRV576AL

Страница 1: ...NANCE_________________________________ 37 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL INSTRUCTIONS FOR THE INSTALLER these are for the qualified technician who must carry out a suitable check of the gas system install the appliance set it functioning and carry out an inspection test INSTRUCTIONS FOR THE USER these contain...

Страница 2: ... CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET M...

Страница 3: ...LE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002 96 EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE THIS GUIDELINE IS THE FRAME OF A EUROPEAN WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT Th...

Страница 4: ... is classified type Y as regards risks against fire and it can be set adjacent to walls that are higher than the work surface provided that a distance of 145 mm is respected as shown in the figure to prevent damage due to overheating Make sure there is a minimum of 750 mm between the hot plate flames and any shelf that may be installed directly above them Accurately position the gasket provided al...

Страница 5: ... on a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily removable to allow access in the event of technical service ...

Страница 6: ...y accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must 2 not be less than 1 0 mm 3 x 1 0 cable keeping in mind that the end to be connected to the hob must have the ground wire yellow green longer by at least 20 mm Use only H05V2V2 F cable or similar which has a maximum temperature of 90 C Any replacement nee...

Страница 7: ...en inspected for G20 2H natural gas at a pressure of 20 mbar For use with other types of gases see Section ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228 1 Connection with rigid copper pipe the connection to the gas mains must not provoke stress of any kind on the hob Connection may be made by using biconical adapter D with insertion of gasket C suppli...

Страница 8: ...r intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid overheating or excess humidity produced by cooking and in the case of lengthy use a window should be opened or the speed of any ventilators should be increased 4 3 Discharge of combustion products D...

Страница 9: ...zzles must be replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the grids the burner caps and the flame caps 2 Remove the screws and the nuts A that secure the burner supports 3 Lift the hob from its seat 4 Replace the burner nozzles in accordance with ...

Страница 10: ... of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Rated LPG G30 G31 28 37 mbar Burner heating capacity Nozzle Reduced diameter By pass Flowrate Flowrate flowrate 1 100 1 100 mm g h G30 g h G31 W mm Auxiliary 1 1 05 48 30 1 380 76 75 Semirapid 2 1 65 62 30 1 380 120 118 Rapid 3 2 55 76 3...

Страница 11: ...irapid 2 1 65 92 380 Rapid 3 2 55 115 650 Rapid large 4 3 1 126 750 Fish pan 7 2 0 100 750 Ultra rapid 5 3 3 130 1200 Internal 1 05 73 380 Double crown 6 External 3 9 140 1200 5 4 Regulation for town gas To allow the unit to work with this type of gas perform the same operations described in paragraph 5 2 Regulation for LPG but choose the nozzles and regulate the primary air for town gas as shown ...

Страница 12: ...110 30 37 mbar 8 mbar Auxiliary 1 1 5 1 0 0 5 Semirapid 2 1 5 1 5 0 5 Rapid 3 1 0 1 5 1 0 Rapid large 4 2 5 10 0 1 5 Fish pan 7 2 0 2 5 1 0 Ultra rapid 5 2 0 2 5 1 5 Internal 3 6 0 1 0 Double crown 6 External 3 0 10 0 5 0 To identify the burners on your hob refer to the drawings in point 6 3 Arrangement of burners on hob ...

Страница 13: ...e model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of minimum for LPG To regulate the minimum for LPG completely tighten clockwise the screw inside or next to the gas tap pin depending on the model The diameters of the by passes for each burner are give...

Страница 14: ...s 1 Auxiliary 2 Semirapid 3 Rapid 4 Rapid large 5 Ultra rapid 6 Double crown 7 Fish pan 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to be cleaned inside and re greased This must be done by a qualified technician ...

Страница 15: ...s a long one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which allow both burners to be used at the same time or to select one or the other as required The device is fit with electronic ignition Simply press and simultaneously turn the knob counter clockwise on the low po...

Страница 16: ...at 7 3 Diameter of the pans Burners Ø min and max in cm Auxiliary 7 18 Semirapid 10 24 Rapid 12 24 Rapid large 14 26 Double crown 12 28 Ultrarapid 22 28 Fish burner Special oval shaped vessels 7 4 Using a griddle plate A few precautions are necessary if you wish to use a griddle plate leave a gap of at least 160 mm between the edge of the griddle plate and the side wall if one of the burners close...

Страница 17: ...rve the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroughly and dry with a soft cloth or deerskin 8 1 2 Food stains or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products and remove spots ...

Страница 18: ...water using a non abrasive detergent taking care to remove all tough spots Before remounting allow the components to fully dry out In fact humidity residues inside the burner holes might impair burner operation 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs and the safety devices keep them very clean Check frequently and clean with a damp cloth when nec...

Отзывы: