Installation
75
EN
Burner and nozzle characteristics tables
The nozzles not provided are available at Authorised Service Centres.
Natural Gas G20 – 20 mbar
AUX
SR
R
Rated heating capacity (kW)
1.05
1.8
3.0
Nozzle diameter (1/100 mm)
72
97
115
Pre-chamber (printed on nozzle)
(X)
(Z)
(Y)
Reduced flow rate (W)
400
500
800
Natural gas G25 - 25 mbar / G25.3 - 25 mbar
AUX
SR
R
Rated heating capacity (kW)
1.05
1.8
3.0
Nozzle diameter (1/100 mm)
72
94
121
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F2)
Reduced flow rate (W)
400
500
800
4 LPG G30/31 mbar
AUX
SR
R
Rated heating capacity (kW)
1.05
1.8
3.0
Nozzle diameter (1/100 mm)
50
65
85
Pre-chamber (printed on nozzle)
-
-
-
Reduced flow rate (W)
400
500
800
Rated flow rate G30 (g/h)
76
131
218
Rated flow rate G31 (g/h)
75
129
215
Appliance set for:
G+ Groningen Group K gas
G25 (2L) - 25 mbar
G25.3 (2K) - 25 mbar