Instructions for the installer
31
5.3
Regulation for natural gas
The hob has been inspected for
G25
(2L 3B/P) at a pressure of 2 mbar.
To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Rated
heating
capacity
(kW)
Natural gas – G25
25 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary (1)
1.05
76
380
Semi-rapid (2)
1.65
98
380
Rapid (3)
2.7
123
650
Rapid (4)
3.1
130
750
Ultra rapid (5)
3.9
150
1400
5.4
Regulation of primary air
Referred to distance “
X
” in mm.
BURNER
G25
25 mbar
G30/G31
28/37 mbar
Auxiliary (1)
1.5
2.0
Semi-rapid (2)
1.0
1.5
Rapid (3)
1.0
5.0
Rapid (4)
1.5
10.0
Ultra rapid (5)
1.5
4.0