background image

 

Instructions for the installer

 

 

28 

 

 

4.1

 

Connection to LPG 

 

   

 

 Use a pressure regulator and make the connection to the tank 

according to the provisions of standards regulations in force. Make 
sure that feed pressure conforms to the levels shown in the table in 
paragraph “5.2  Regulation for LPG”. 

 

   

 

 

4.2

 

Ventilation of rooms 

 

   

 

  The hob may be installed only in rooms with permanent ventilation, as 

required by standards regulations in force. The room in which the hob 
is installed must have sufficient air flow to satisfy the requirements of 
normal gas combustion and of necessary air exchange in the room. 
The air intakes, protected by screens, must be appropriately sized 
(regulations in force) and placed so as not to be blocked in any way. 
The room where the oven is installed should be suitably ventilated to 
avoid overheating or excess humidity produced by cooking, and in the 
case of lengthy use a window should be opened or the speed of any 
ventilators should be increased. 

 

   

 

 

4.3

 

Discharge of combustion products 

 

   

 

 Discharge of combustion products must be guaranteed by means of 

hoods connected to a natural draught flue with certain efficiency, or by 
means of forced aspiration. 
An efficient aspiration system requires careful planning by a specialist 
capable of installing it, respecting the positions and distances 
prescribed 
by standards. After installation, the installer must issue a certificate of 
conformity. 

Содержание SNL574GH

Страница 1: ...USING THE HOB______________________________________________ 34 8 CLEANING AND MAINTENANCE_________________________________ 36 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICA...

Страница 2: ...CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPE...

Страница 3: ...E PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN...

Страница 4: ...is classified type Y as regards risks against fire and it can be set adjacent to walls that are higher than the work surface provided that a distance of 145 mm is respected as shown in the figure to p...

Страница 5: ...on a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily re...

Страница 6: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 0 mm 2 3 x 1 0 cable keeping in mind...

Страница 7: ...inspected for G25 2L3B P natural gas at a pressure of 25 mbar For use with other types of gases see Section ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 7...

Страница 8: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Страница 9: ...replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the...

Страница 10: ...ation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Burner Rated heating capacity LP...

Страница 11: ...h sealing wax or equivalent material Burner Rated heating capacity Natural gas G25 25 mbar Nozzle diameter 1 100 mm Reduced flowrate W Auxiliary 1 05 76 380 Semirapid 1 65 98 380 Rapid 2 7 123 650 Rap...

Страница 12: ...model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of...

Страница 13: ...iary 2 Semirapid 3 Rapid 4 Rapid large 6 Ultra rapid 7 Double crown 8 Fish pan 10 Double crown 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it...

Страница 14: ...ong one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which allow both bur...

Страница 15: ...Diameter of the pans Burners min and max in cm Auxiliary 7 18 Semirapid 10 24 Rapid 12 24 Double crown 22 26 Ultrarapid 22 26 Fish burner Special oval shaped vessels 7 4 Using a griddle plate A few pr...

Страница 16: ...ve the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoro...

Страница 17: ...ater using a non abrasive detergent taking care to remove all tough spots Before remounting allow the components to fully dry out In fact humidity residues inside the burner holes might impair burner...

Отзывы: