background image

 

Instructions for the installer 

 

32 

 

 

5.3

 

Regulation for LPG 

 

 

 

 

 Check that the connection has been made as described in the “Gas 

connection” section. 
Undo the screw “

D

” and push the air regulator “

C

” fully down. Use a 

spanner to remove the nozzles “

B

” and fit those of suitable type 

following the instructions given in the tables for bottled gas G30/G31 –
28/37 mbar. The nozzle must not be tightened to a torque of over 3 
Nm. Regulate the air flow by moving the Venturi pipe “

C

”, until the gap 

A

” is as shown in the table in point “5.5 Regulation of primary air” and 

fix it with the screw “

D

”.  After making the adjustments, restore the 

seals with sealing wax or an equivalent material.

 

 

   

 

 

 

 

 

   

Burner 

Rated 

heating 

capacity 

LPG – G30/G31

 28/37 mbar 

 

 

Nozzle 

Diameter 

1/100 

mm 

By-pass 

1/100 

mm 

Reduced 

flowrate 

(W) 

Flowrate 

g/h G30 

Flowrate 

g/h G31 

 

Auxiliary 

1.05 

48 

30 

360 

76 

75 

 

Semi-rapid

 

1.7 

62 

30 

360 

124 

121 

 

Rapid

 

2.55 

76 

40 

650 

185 

182 

 

Rapid

 

large

 

3.1 

85 

45 

800 

225 

222 

 

Fish pan

 

2.9 

82 

50 

950 

211 

207 

 

Ultra rapid

 

4.0 

95 

65 

1600 

291 

286 

 

Содержание SNL34AX1

Страница 1: ...USING THE HOB______________________________________________ 38 8 CLEANING AND MAINTENANCE_________________________________ 41 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICA...

Страница 2: ...CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPE...

Страница 3: ...E PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN...

Страница 4: ...han the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make sure there is a minimum of 750...

Страница 5: ...90 cm hobs on 60 cm base unit If a 90 cm hob is to be bracketed to a 60 cm base unit 2 central brackets A have to be used in addition to the side brackets B as shown in the drawing below The gas conne...

Страница 6: ...ly accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 mm 2 3 x 1 cable keeping in mind th...

Страница 7: ...inspected for G25 2L3B P natural gas at a pressure of 25 mbar For use with other types of gases see Section ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228...

Страница 8: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Страница 9: ...and the knob guard tube A by pulling them up 2 Use a crosshead screwdriver to remove the screws and the two cylindrical supports B 3 Raise the left hand side of the control panel slightly and shift i...

Страница 10: ...er 3 Nm Regulate the air flow by moving the Venturi pipe C until the gap A is as shown in the table in point 5 5 Regulation of primary air and fix it with the screw D After making the adjustments rest...

Страница 11: ...he nozzles and regulate the primary air for natural gas as shown in the following table and in paragraph 5 5 Regulation of primary air After the regulations have been carried out restore the seals wit...

Страница 12: ...0 4 0 90 cm hobs with separable control panel Burner G25 25 mbar G30 G31 28 37 mbar Auxiliary 1 2 0 2 5 Semirapid 2 0 5 2 0 Rapid 3 0 5 1 5 Fish burner 4 1 0 8 0 Ultrarapid 5 1 5 5 5 60 cm hob with bu...

Страница 13: ...ap pin depending on the model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go...

Страница 14: ...3 Arrangement of the burners on the hob Hob with separable control panel 60 cm hob BURNERS 1 Auxiliary 2 Semirapid r 3 Semirapid l 4 Rapid large 5 Ultrarapid 90 cm hob BURNERS 1 Auxiliary 2 Semirapid...

Страница 15: ...ilt in control panel 60 cm hob BURNERS 1 Auxiliary 2 Semirapid r 3 Semirapid l 4 Rapid 5 Ultrarapid 6 5 Lubrication of gas taps With time it may happen that the gas taps get blocked and hard to turn C...

Страница 16: ...knob has to be turned to the ignition symbol before it is pressed and after ignition the knob has to be kept pressed for about 2 seconds to keep the flame lit and to activate the safety device The bur...

Страница 17: ...ments Hobs may be fitted with an electric element of varying diameter The electric element is controlled by a switch and is turned on by rotating the appropriate knob to the desired position 7 4 2 Usi...

Страница 18: ...ppliance The electric elements will stay hot for a long time after use do not touch them or place any objects on them If any dents appear in the electric element surface switch it off immediately and...

Страница 19: ...the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroug...

Страница 20: ...mponents to fully dry out In fact humidity residues inside the burner holes might impair burner operation 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs an...

Отзывы: