background image

 

 

Instructions for the installer

 

 

4.1

 

Connection to LPG 

 

Use a pressure regulator and make the connection to the tank according 
to the provisions of standards regulations in force. Make sure that feed 
pressure conforms to the levels shown in the table in paragraph “5.2 
Regulation for LPG”. 
 
 
 

 

4.2

 

Ventilation of rooms 

 

 

The hob may be installed only in rooms with permanent ventilation, as 
required by standards regulations in force. The room in which the hob is 
installed must have sufficient air flow to satisfy the requirements of 
normal gas combustion and of necessary air exchange in the room. The 
air intakes, protected by screens, must be appropriately sized 
(regulations in force) and placed so as not to be blocked in any way. 
The room where the oven is installed should be suitably ventilated to 
avoid overheating or excess humidity produced by cooking, and in the 
case of lengthy use a window should be opened or the speed of any 
ventilators should be increased. 

 
 
 

4.3

 

Discharge of combustion products 

 

 

Discharge of combustion products must be guaranteed by means of 
hoods connected to a natural draught flue with certain efficiency, or by 
means of forced aspiration. 
An efficient aspiration system requires careful planning by a specialist 
capable of installing it, respecting the positions and distances prescribed 
by standards. After installation, the installer must issue a certificate of 
conformity. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

28

 

Содержание SLRV596X1

Страница 1: ..._______________________________________ 34 8 CLEANING AND MAINTENANCE ___________________________ 37 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE...

Страница 2: ...DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS...

Страница 3: ...LE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEA...

Страница 4: ...nted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make sur...

Страница 5: ...a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily remov...

Страница 6: ...cessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 5 mm 2 3 x 1 5 cable keeping in mind tha...

Страница 7: ...n inspected for G25 2L 3B P at a pressure of 25 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228 1 Conn...

Страница 8: ...takes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid ov...

Страница 9: ...ced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the grid...

Страница 10: ...icated in the chart in paragraph 5 4 Regulation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent...

Страница 11: ...t restore the seals with sealing wax or equivalent material Burner Rated heating capacity kW G25 25 mbar Nozzle diameter 1 100 mm Reduced flowrate W Auxiliary 1 1 05 76 380 Semi rapid 2 1 65 98 380 Ra...

Страница 12: ...model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of m...

Страница 13: ...uxiliary 2 Semi rapid 3 Rapid 4 Ultra rapid 5 Double crown 6 Fish pan 7 Ultra rapid 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to be c...

Страница 14: ...ng one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which permit to use b...

Страница 15: ...ence numbers see page 33 7 4 Using a griddle plate A few precautions are necessary if you wish to use a griddle plate leave a gap of at least 160 mm between the edge of the griddle plate and the side...

Страница 16: ...h boiling point to roast delicate meat or fish 5 Strong For roasts steaks and large boiled joints 3 6 Very strong To boil large amounts of water to fry WARNING When switching on the electric element f...

Страница 17: ...e surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroughly...

Страница 18: ...roducts for appliance cleaning and care 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs and the safety devices keep them very clean Check frequently and cle...

Отзывы: