
EN20
ERROR CODE
DESCRIPTION
POSSIBLE CAUSES
ERROR ELIMINATION
The hob switches off and after 30 seconds
emits an acoustic signal every 10 seconds.
Permanent pressure on the control
zone.
Water or kitchen utensils on the control
zone.
Clean the control zone.
C81, C82, C83
The control panel switches off because
of excessively high temperatures.
The internal temperature of electronic
parts is too high.
Wait for the hob to cool down
before using it again.
F42 or F43
The connection voltage is wrong.
The sensor detects a discrepancy
between the appliance voltage and that
of the mains supply.
Disconnect the hob from the mains
and check the electrical connection.
F12, F21, F25, F36, F37, F40, F47, F56,
F58,
F60, F61, F62, F63, F64
Call the After-sales Service and specify the error code.
Содержание SIM592B
Страница 1: ......
Страница 4: ...3 3 4 5...
Страница 14: ...5019 600 00980 11 12 PL DK SE FR NL ES GB DE IT RU PT AE...