background image

 

 

Содержание SHW900B

Страница 1: ...Instructions Manual SHW900B ...

Страница 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 10 EN ...

Страница 3: ...e thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation ...

Страница 4: ...er Section 2 2 1 Lower Section 9 1 Reducer Flange ø 150 120 mm 10 1 Damper ø 150 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3 1 Air Outlet Connection Support 11 8 Wall Plugs 12a 8 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual ...

Страница 5: ...EN 5 5 Dimensions Min 650mm Min 650mm ...

Страница 6: ...w the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre points marked Insert the...

Страница 7: ...per 10 Fix the pipe in position using sufficient pipe clamps not sup plied To install a ø 120 pipe To install a ø 120 mm air exhaust connection insert the re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoal filters 9 ø120 ø150 10 10 RECIRCULATION VERSION AIR OUTLET Insert the connection extension pieces laterally 14 1...

Страница 8: ...n the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and hook them be tween the upper flue and the wall making sure ...

Страница 9: ...ble to change the op erating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 seconds to activate Intensive speed which is timed to run for 10 minutes At the end of this time it will automatically return to the speed set before Suitable to deal with maximum levels of cooking fumes ...

Страница 10: ...n REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently for particularly heavy usage Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Refit the metal grease filters Lighti...

Страница 11: ......

Страница 12: ...436006006_ver3 ...