background image

 

 

 

 

 

EN 

1

10 

USE

 

L

L1

T1

T2

T3

T4

L2

L3

L4

 

Control panel 

But
ton 

Function Led 

Turns the lighting system on and off. 

-  

 

Press and hold for approx. 2 seconds to turn the lighting 
system on and off at reduced intensity. 

T1 

Turn the suction motor on and off at speed one.  

On. 

 

Press and hold the button for approximately 2 seconds, 
with all the loads turned off (Motor and Lights), to reset 
the Filters and turn off the Leds that are lit.  

After 100 working hours all the 
LEDs (L1-L2-L3-L4) will light up 
and remain lit to indicate saturation 
of the metal grease filters.  
After 200 working hours all the 
LEDs (L1-L2-L3-L4) will light up 
and start to flash to indicate 
saturation of the activated charcoal 
filters. 

T2 

Turn the suction motor on at speed two.  

On. 

 

Press and hold for approximately 5 seconds, with all the 
loads turned off (Motor and Lights), to enable/disable 
the Remote control.  

2 flashes, Remote control Enabled. 
1 flash, Remote control Disabled. 

T3 

Turn the suction motor on at speed three. 

On.  

 

Press and hold the button for 2 seconds to activate 
intensive speed. This speed is timed to run for 10 
minutes. At the end of this time the system will 
automatically return to the speed set before. 

 

T4 

Press and hold the button for approximately 2 seconds to 
activate automatic shutdown with a 30' delay 
(Motor+Lights).  

On. 
 

 

Press and hold for approximately 5 seconds to 
enable/disable the Activated Charcoal Filter alarm. 

2 Flashes of the Leds (L1-L2-L3) 
Filter Alarm Enabled.  
1 Flash of the Leds (L1-L2-L3) 
Filter Alarm Disabled. 

Содержание SHI410X

Страница 1: ...Instructions Manual SHI410X ...

Страница 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 10 MAINTENANCE 11 EN ...

Страница 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Страница 4: ...rame 9 1 Reducer Flange ø 150 120 mm 10 1 Flange ø 120 mm 10a 1 Dumper 15 1 Recirculation Air Outlet Connection 25 2 Pipe clamps Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12c 4 Screws 2 9 x 6 5 12f 4 Screws M6 x 10 12g 4 Screws M6 x 80 12h 4 Screws 5 2 x 70 21 1 Drilling template 22 4 6 4 mm int dia washers 23 4 M6 nuts Q ty Documentation 1 Instruction Manual 2 11 12h 22 23 21 7 1 1 12...

Страница 5: ...EN 5 5 Dimensions Dimensions of the hood in ducting version Dimensions of the hood in recycling version 650mm minimum ...

Страница 6: ...ings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and ...

Страница 7: ...to the upper part of the frame using four 12c screws supplied with the hood Fix the flange ø120 10 to the lower part of the recy cling air outlet 15 Put the reducer flange 9 on the hood body outlet At this point join the flanges with a pipe In order to calculate the height of the pipe it is necessary to es timate the height of the hood mm and subtract 615 mm H pipe H hood 615 Lengthen the frame so...

Страница 8: ...d Appliance After fixing make sure that the base is stable even when the Frame is subjected to lateral stress If the Ceiling is not strong enough in the area where the hood is to be fixed the Installer must strengthen the area using suitable plates and counterplates an chored to resistant structures 2 1 1 2 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect th...

Страница 9: ...ling downwards Remove possible charcoal filters In order to fix the hood body to the frame insert the 4 screws 12f in their seats It is necessary to leave at least 4 5 mm gap between the screw heads and the frame plate Hook the hood canopy to the frame and turn it to the left until it reaches the stop then lock the screws im mediately to prevent the hood canopy from falling out accidentally 2 1 EL...

Страница 10: ...saturation of the activated charcoal filters T2 Turn the suction motor on at speed two On Press and hold for approximately 5 seconds with all the loads turned off Motor and Lights to enable disable the Remote control 2 flashes Remote control Enabled 1 flash Remote control Disabled T3 Turn the suction motor on at speed three On Press and hold the button for 2 seconds to activate intensive speed Thi...

Страница 11: ...larly intensive Resetting the alarm signal Press button T1 see the paragraph on Use Cleaning the Filters Open the lighting unit by pulling on the nocth Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and leave them to dry completely before replacing Replace taking care to ensure that the handle f...

Страница 12: ...rm ACTIVATED Leds L1 L2 L3 flash once Activated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press button T1 see the paragraph on Use Changing the Filter Open the lighting unit by pulling on the nocth Remove the Metal grease filters Remove the saturated Activated Charcoal filter as shown in the figure Fit the new Filter hooking it ...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...991 0263 497_ver1 ...

Отзывы: