background image

Instructions for the installer 

 

 

30 

 

 

4.1

 

Connection to LPG 

 

 

 

 

 Use a pressure regulator and make the connection to the tank 

according to the provisions of standards regulations in force. Make sure 
that feed pressure conforms to the levels shown in the table in 
paragraph “5.3  Regulation for LPG”. 

 

   

 

 

4.2

 

Ventilation of rooms 

 

 

 

 

  The hob may be installed only in rooms with permanent ventilation, as 

required by standards regulations in force. The room in which the hob 
is installed must have sufficient air flow to satisfy the requirements of 
normal gas combustion and of necessary air exchange in the room. 
The air intakes, protected by screens, must be appropriately sized 
(regulations in force) and placed so as not to be blocked in any way. 
The room where the oven is installed should be suitably ventilated to 
avoid overheating or excess humidity produced by cooking, and in the 
case of lengthy use a window should be opened or the speed of any 
ventilators should be increased. 

 

   

 

 

4.3

 

Discharge of combustion products 

 

 

 

 

 Discharge of combustion products must be guaranteed by means of 

hoods connected to a natural draught flue with certain efficiency, or by 
means of forced aspiration. 
An efficient aspiration system requires careful planning by a specialist 
capable of installing it, respecting the positions and distances 
prescribed by standards. After installation, the installer must issue a 
certificate of conformity. 

Содержание SER64XGNL

Страница 1: ...USING THE HOB______________________________________________ 38 8 CLEANING AND MAINTENANCE_________________________________ 41 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICA...

Страница 2: ...CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPE...

Страница 3: ...E PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN...

Страница 4: ...han the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make sure there is a minimum of 750...

Страница 5: ...90 cm hobs on 60 cm base unit If a 90 cm hob is to be bracketed to a 60 cm base unit 2 central brackets A have to be used in addition to the side brackets B as shown in the drawing below The gas conne...

Страница 6: ...ly accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 mm 2 3 x 1 cable keeping in mind th...

Страница 7: ...inspected for G25 2L3B P natural gas at a pressure of 25 mbar For use with other types of gases see Section ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228...

Страница 8: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Страница 9: ...crosshead screwdriver to remove the screws and the two cylindrical supports B 3 Raise the left hand side of the control panel slightly and shift it to the right to remove it completely 4 In models wi...

Страница 10: ...with the screw D After making the adjustments restore the seals with sealing wax or an equivalent material Burner Rated heating LPG G30 G31 28 37 mbar capacity Nozzle Diameter 1 100 mm By pass 1 100 m...

Страница 11: ...he nozzles and regulate the primary air for natural gas as shown in the following table and in paragraph 5 5 Regulation of primary air After the regulations have been carried out restore the seals wit...

Страница 12: ...0 4 0 90 cm hobs with separable control panel Burner G25 25 mbar G30 G31 28 37 mbar Auxiliary 1 2 0 2 5 Semirapid 2 0 5 2 0 Rapid 3 0 5 1 5 Fish burner 4 1 0 8 0 Ultrarapid 5 1 5 5 5 60 cm hob with bu...

Страница 13: ...of the cock stem until a steady minimum flame is achieved Refit the knob and verify the burner flame is stable turning the knob rapidly from the maximum to the minimum position the flame must not go...

Страница 14: ...3 Arrangement of the burners on the hob Hob with separable control panel 60 cm hob BURNERS 1 Auxiliary 2 Semirapid r 3 Semirapid l 4 Rapid large 5 Ultrarapid 90 cm hob BURNERS 1 Auxiliary 2 Semirapid...

Страница 15: ...ilt in control panel 60 cm hob BURNERS 1 Auxiliary 2 Semirapid r 3 Semirapid l 4 Rapid 5 Ultrarapid 6 5 Lubrication of gas taps With time it may happen that the gas taps get blocked and hard to turn C...

Страница 16: ...knob has to be turned to the ignition symbol before it is pressed and after ignition the knob has to be kept pressed for about 2 seconds to keep the flame lit and to activate the safety device The bur...

Страница 17: ...ments Hobs may be fitted with an electric element of varying diameter The electric element is controlled by a switch and is turned on by rotating the appropriate knob to the desired position 7 4 2 Usi...

Страница 18: ...ppliance The electric elements will stay hot for a long time after use do not touch them or place any objects on them If any dents appear in the electric element surface switch it off immediately and...

Страница 19: ...the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroug...

Страница 20: ...mponents to fully dry out In fact humidity residues inside the burner holes might impair burner operation 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs an...

Отзывы: