Instructions for the installer
11
5
ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the
appliance from the electrical socket.
The hob has been inspected for
LPG
at a pressure of 30 mbar.
5.1
Removing the separable control panel
(models with
separable control panel)
1.
Remove the knobs and the knob
guard tube “
A
” by pulling them up;
2.
Use a crosshead screwdriver to
remove the screws and the two
cylindrical supports “
B
”;
3.
Raise the left-hand side of the
control panel slightly and shift it to
the right to remove it completely;
4.
In models with electric hotplate, the
body of the pilot light has to be
removed to free the control panel;
5.2
Removing the hob
(models with integrated control
panel)
1.
Remove the knobs, the
griddles, the burner caps, the
flame caps and the two rear
plugs;
2.
Remove the screws “
A
”
which fix the burner supports;
3.
Raise the hob, sliding it off
the ignition plugs and/or the
thermocouples and the gas
tap rods;