Smeg SC709XU Скачать руководство пользователя страница 6

Instructions for the Installer

8

US INSTALLATION ONLY – 3 WIRE BRANCH CIRCUIT

Refer to 

figure 1

, where local codes allow the

connection of the ground wire from the applliance
to the branch circuit neutral wire (white wire):

-  The ground wire must be connected first;

-  If local codes permit, connect the green or

yellow-green ground wire from the appliance
and the white wire from the appliance to the
branch circuit neutral wire (white wire).

-  Connect the red and black leads from the oven

to the corresponding leads in the junction box. 

 fig.1)

US INSTALLATION AND CANADIAN INSTALLATION – 4 WIRE BRANCH CIRCUIT

Refer to 

figure 2

-  Disconnect the green or yellow-green from the

white lead.

-  The ground wire must be connected first;

-  Connect the green or yellow-green ground wire

from the appliance to the ground in the junction
box (green colored wire). 

Do not connect the

grounding wire to the neutral wire in the
junction box.

-  Connect the red and black leads from the

appliance to the corresponding leads in the
junction box.

-  Connect the white wire from the appliance to the

neutral (white) wire in the junction box. 

 fig.2)

Connect to a 20A fuse or circuit breaker. Connect to copper wire only, or, if connecting to
aluminum house wire, use UL-listed or CSA-approved connectors, which are suitable for joining
aluminum with copper wires.