Starting-up
•
Start up / switch off the hob:
Action
Control panel
Display
To start
Press key [ 0/I ]
[ 0 ] are blinking
To stop
Press key [ 0/I ]
Nothing or [ H ]
•
Start up / switch off a heating zone:
Action
Control panel
Display
Zone selection
Press on the “SLIDER“
[ 0 ] and control
across from the desired zone
light on
To set
Slide on the “SLIDER“
[ 0 ] to [ 9 ]
(adjust the power)
to the right or to the left
To stop
Slide to [ 0 ] on “SLIDER“
[ 0 ] or [ H ]
or press on [ 0 ]
[ 0 ] or [ H ]
If no action is made within 20 second the electronics returns in waiting position.
Pan detection
The pan detection ensures a perfect safety. The induction doesn’t work:
•
If there is no pan on the heating zone or if this pan is not adapted to the induction. In this
case it is impossible to increase the power and the display shows [ U ]. This symbol
disappears when a pan is put on the heating zone.
•
If the pan is removed from the heating zone the operation is stopped. The display shows
[ U ]. The symbol [ U ] disappears when the pan is put back to the heating zone. The
cooking continues with the power level set before.
After use, switch the heat element off: don’t let the pan detection [ U ] active.
Residual heat indication
After swittching off of a heating zone or the complete stop of the hob, the heating zones are still
hot and indicates [ H ] on the display.
The symbol [ H ] disappears when the heating zones may be touched without danger.
As far as the residual heat indicators are on, don’t touch the heating zones and don’t put any heat
sensitive object on them. There are risks of burn and fire.