Instructions for the installer
21
14.ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the appliance from the mains.
The hob of the cooker is adjusted for use with
natural gas
at a pressure of 1.0kPa. If used with other
types of gas, you have to replace the nozzles and regulate the primary air to the burners. Then adjust
the minimum flame on the gas taps. For nozzle replacement and burner adjustment you must raise the
hob as described in the following paragraph.
14.1 Replacement of nozzles on the hob
1 Extract the grids and remove all the caps and flame-spreader crowns;
2 Unscrew the burner nozzles with a 7 mm socket wrench;
3 Replace the nozzles according to the type of gas to be used and the description in paragraph "14.2
Burner and nozzle characteristics table ";
4 Replace the burners in the correct position.