Installation
20
Due to problems of overall dimensions at
the back, screw in the pressure regulator so
that it is sloped at 45° vs the wall at the
back of the appliance.
Test the appliance
Follow these instructions to leak test the
appliance:
Use a brush and liquid detergent to test all
gas connections for leaks. Bubbles around
connections indicate a leak. If a leak
appears, shut off the gas valve controls and
adjust the connections. Then check the
connections again. Remove all the
detergent product from the range. Replace
the parts on the burner and turn the knobs
on the gas tap valves.
NEVER TEST FOR GAS LEAKS WITH A
MATCH OR OTHER FLAMES.
Shut-off valve
The supply line must be fitted with an
approved shut-off valve.
This valve should be located in the same
room as the range and should be in a
location where it can be easily opened and
closed.
Do not block access to the shut-off valve.
The valve is necessary for turning the gas to
the appliance on or off.