16

GAS TRANSFORMATIONS AND ADJUSTMENTS

Replacing the nozzles

If the equipment is adjusted for a type of gas that 

is different from the one available, it is necessary 

to replace the burner nozzles.

The  choice  of  the  nozzles  to  replace  must  be 

made according to the table of the “technical cha-

racteristics”.

Act as follows:

- Remove the racks and burners.

-  by  means  of  a  straight  spanner  L,  unscrew  the 

nozzle  U  (fig.7)  and  substitute  it  with  the  corre-

sponding one.

- tighten the nozzle strongly.

Adjusting the burners

The  lowest  flame  point  must  always  be  properly 

adjusted  and  the  flame  must  remain  on  even  if 

there  is  an  abrupt  shift  from  the  maximum  to  the 

minimum position.

If this is not so, it is necessary to adjust the lowest 

flame point as follows:

- start the burner up

-  turn  the  tap  up  to  the  minimum  position  (small 

flame)

- remove the knob from the tap rod

- introduce a flat-tip screwdriver C in the hole F of 

the tap (fig.8) and turn the by-pass screw up to a 

proper adjustment of the lowest flame point.

As regards G30 gas burners, the by-pass screw 

must be tightened completely.

7

8

Replacing the battery (fig. 9)

- Unscrew the cap 

T .

- Replace  the  battery 

type  alkaline AA  1,5  V 

placing it  in  the  spring 

M

  and  making  sure  that 

the “ 

-

 

” polarity faces upwards.

- Fit the battery into the battery holder and screw 

down the cap 

T.

9

Содержание S863VG3

Страница 1: ...IT ISTRUZIONI PER L INSTALLAZIONE E L USO DEL PIANO DI COTTURA CRISTALLO A GAS GB INSTRUCTIONS FOR THE INSTALLATION AND USE OF GLASS GAS COOK TOPS...

Страница 2: ...ing watch the children and make sure they neither stay near the equipment nor touch the surfaces that have not cooled down completely Before powering the equipment check that it is properly adjusted f...

Страница 3: ...11 descriPTION MOD S863VG3 2 Semi rapid burner 1650 W 4 Wok burner 4000 W 7 Battery housing 8 Control knob for burner...

Страница 4: ...All of the operating positions must be chosen between the maximum and the minimum ones never between the minimum position and the closing point The gas supply can be interrupted by turning the knob cl...

Страница 5: ...ed surfaces for a long time Burners and racks These parts can be removed to make cleaning easier The burners must be washed with a sponge and soapy water or with a light detergent wiped well and place...

Страница 6: ...ure The walls of the pieces of furniture must resist a temperature of 65 C besides the room one The equipment must not be installed near inflammable materials such as curtains cloths etc Make a hole i...

Страница 7: ...come from permanent openings made on the room walls that communicate with the outside The section of these openings shall correspond to at least 200 cm2 Gas connection Make sure that the appliance is...

Страница 8: ...djusted and the flame must remain on even if there is an abrupt shift from the maximum to the minimum position If this is not so it is necessary to adjust the lowest flame point as follows start the b...

Страница 9: ...c refuse at the end of its useful life It must therefore be delivered to a waste recycling centre specifically for electric and electronic equipment or returned to the retailer at the moment of purcha...

Страница 10: ...20 COD 208327 00 26 05 2009...

Отзывы: