![Smeg PVL664CN Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/smeg/pvl664cn/pvl664cn_manual_1302894025.webp)
Installation
53
EN
The nozzles not provided are available at Authorised Service Centres.
6
LPG G30/31
AUX
SR
RR
R
UR
Rated heating capacity (kW)
1.0
1.60
2.50
2.90
3.50
Nozzle diameter (1/100 mm)
46
58
72
76
85
Reduced flow rate (W)
450
550
950
950
1300
Primary air (mm)
10
10
10
10
10
Marking on nozzle
-
-
-
-
-
Rated flow rate G30 (g/h)
73
116
182
211
254
Rated flow rate G31 (g/h)
71
114
179
207
250
7
Town Gas G110
AUX
SR
RR
R
UR
Rated heating capacity (kW)
1.0
1.6
2.5
2.9
3.4
Nozzle diameter (1/100 mm)
130
165
220
245
280
Reduced flow rate (W)
400
500
900
900
1100
Primary air (mm)
OPEN
OPEN
4
4
4
Marking on nozzle
H2
H3
H1
-
-