Installation
59
EN
Burner and nozzle characteristics tables
1
Natural Gas G20 – 20 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.2
6.0
Nozzle diameter (1/100 mm)
76
95
117
126
148
175
Reduced flow rate (W)
400
500
750
900
1600
1800
Primary air (mm)
1
1
1
1
2
1
2
Natural Gas G20 – 25 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.2
6.0
Nozzle diameter (1/100 mm)
73
87
110
120
140
165
Reduced flow rate (W)
400
500
750
900
1600
1800
Primary air (mm)
1
1
1
1
1.5
0.5
3
Natural Gas G25 – 25 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.5
3.0
4.1
6.0
Nozzle diameter (1/100 mm)
76
95
117
126
148
185
Reduced flow rate (W)
400
500
750
900
1600
1800
Primary air (mm)
1
1
1
1
2
0.5
4
Natural gas G25.1 – 25 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.2
6.0
Nozzle diameter (1/100 mm)
76
98
123
135
160
190
Reduced flow rate (W)
400
500
750
900
1600
1800
Primary air (mm)
1
1
1
1
1.5
0.5
5
Natural Gas G25 – 20 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.2
6.0
Nozzle diameter (1/100 mm)
82
105
126
140
165
200
Reduced flow rate (W)
400
500
750
900
1600
1800
Primary air (mm)
1
1
1
1
1.5
0.5
6
Natural Gas G27 – 20 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.2
5.8
Nozzle diameter (1/100 mm)
82
105
130
145
165
200
Reduced flow rate (W)
400
500
750
900
1600
1800
Primary air (mm)
1
0.5
0.5
1
0.5
0.5
7
Natural gas G2.350 – 13 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.2
6.0
Nozzle diameter (1/100 mm)
100
126
160
175
210
280
Reduced flow rate (W)
400
500
750
900
1600
1800
Primary air (mm)
1
1
1
1
1.5
3