Installation
58
Burner and nozzle specifications tables
1
Natural gas G20 – 20 mbar
SR
R
UR
Rated heating capacity (kW)
1.7
3.1
6.0
Nozzle diameter (1/100 mm)
92
126
175
Reduced flow rate (W)
500
900
1800
Primary air (mm)
1
1
1
2
Natural gas G20 – 25 mbar
SR
R
UR
Rated heating capacity (kW)
1.7
3.1
5.7
Nozzle diameter (1/100 mm)
87
120
160
Reduced flow rate (W)
500
900
1800
Primary air (mm)
1
1
1
3
Natural Gas G25 – 25 mbar
SR
R
UR
Rated heating capacity (kW)
1.7
3.1
6.0
Nozzle diameter (1/100 mm)
95
130
185
Reduced flow rate (W)
500
900
1800
Primary air (mm)
1
1
0.5
4
Natural gas G25.1 – 25 mbar
SR
R
UR
Rated heating capacity (kW)
1.7
3.1
5.9
Nozzle diameter (1/100 mm)
98
135
190
Reduced flow rate (W)
500
900
1800
Primary air (mm)
1
1
0.5
5
Natural Gas G25 – 20 mbar
SR
R
UR
Rated heating capacity (kW)
1.7
3.1
6.0
Nozzle diameter (1/100 mm)
100
140
200
Reduced flow rate (W)
500
900
1800
Primary air (mm)
1
1
0.5
6
Natural Gas G27 – 20 mbar
SR
R
UR
Rated heating capacity (kW)
1.7
3.1
5.8
Nozzle diameter (1/100 mm)
105
145
200
Reduced flow rate (W)
500
900
1800
Primary air (mm)
1
0.5
0.5
7
Natural gas G2.350 – 13 mbar
SR
R
UR
Rated heating capacity (kW)
1.7
3.1
6.0
Nozzle diameter (1/100 mm)
126
175
280
Reduced flow rate (W)
500
900
1800
Primary air (mm)
1
1
3
Содержание PV331CN