Installation
45
EN
5.6 Adaptation to different types of
gas
If other types of gas are to be used, the
nozzles must be replaced and the primary
air must be adjusted. In order to replace the
nozzles and adjust the burners, the hob top
must be removed.
Removing the hob top
1. Remove the grids from the hob.
2. Remove the flame-spreader crowns and
relative burner caps.
3. Pull the knobs upwards to remove them.
4. Unscrew the burner rings using the
supplied wrench.
The appliance is preset for natural
gas G20 (2H) at a pressure of 20
mbar.