background image

Instructions for the Installer

8

3.1 Gas supply requirements

  WARNING

EXPLOSION HAZARD

-  Use a new AGA- or CSA-approved gas supply line.

-  Install a shut-off valve.

-  Securely tighten all gas connections.

-  lf connected to LP, have a qualified technician ensure that gas pressure

does not exceed a 14" water column.

-  Examples of qualified technicians include licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

-  Failure to do so can result in death, explosion, or fire.

NOTE: 

 

- observe all government codes and ordinances.
- The cooktop must be connected to a regular gas supply.

1)

This installation must conform to local codes and ordinances. In the absence of local codes, installations
must conform to American National Standards, National Fuel Gas Code ANSI Z223.1 - latest edition** or
CANI 13149.1 or 2**.

2)

If local codes permit, a flexible metal appliance connector with the new AGA- or CSAcertified design, 4-5
feet (1.2-1.5 m) long, 1/2" or 3/4" I.D., is recommended for connecting this cooktop to the gas supply line.
Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator has 3/8
female pipe threads. You will need to determine the fittings required, depending on the size of your gas
supply line, the flexible metal connector and the shut-off valve.

3)

The supply line shall be equipped with an approved shut-off valve.
This valve should be located in the same room as the cooktop and
should be in a location that allows for easy opening and closing.
Do not block access to the shut-off valve. The valve is necessary for
turning the gas to the appliance on or off.

Содержание PU106

Страница 1: ...TOP AND LOCATION REQUIREMENTS 6 3 1 Gas supply requirements 8 3 2 Electrical requirements 9 4 INSTALLING THE COOKTOP 11 5 CHECKING OPERATION 14 6 WIRING DIAGRAMS 15 INSTRUCTIONS FOR THE INSTALLER these are intended for the qualified engineer who is able to install commission and test the appliance 3 ...

Страница 2: ...vernment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not attempt to switch on any appliances Do not touch any...

Страница 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS ...

Страница 4: ...ere cooktops is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section To prevent accidents or ruining the mobile components of the appliance the following steps must be t...

Страница 5: ... 1 8 483 485 mm 8 1 4 210 mm 3 3 8 86 mm 1 7 16 36 mm 1 3 4 45 mm 27 1 2 700 mm 39 3 8 1000 mm 33 11 16 33 14 16 855 860 mm 19 1 8 19 5 16 485 490 mm 8 1 4 210 mm 4 7 16 112 mm 1 7 16 36 mm 1 3 4 45 mm 39 3 8 1000 mm Gas line opening Wall everywhere 5 12 7 cm below underside of countertop Cabinet base everywhere within 6 15 2 cm from rear wall is recommended Grounded outlet Locate within 24 61 cm ...

Страница 6: ...s must conform to American National Standards National Fuel Gas Code ANSI Z223 1 latest edition or CANI 13149 1 or 2 2 If local codes permit a flexible metal appliance connector with the new AGA or CSAcertified design 4 5 feet 1 2 1 5 m long 1 2 or 3 4 I D is recommended for connecting this cooktop to the gas supply line Do not bend or damage the flexible connector when moving the cooktop The pres...

Страница 7: ...stem by closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an oven the gas pipe must not pass along the back of the oven as this may cause overheating 3 2 Electrical requirements WARNING ELECTRICAL SHOCK HAZARD Plug into a grounded 3 prong outlet Do not ...

Страница 8: ...NSI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the customer to have a properly polarized and grounded 3 prong outlet installed by a qualified electrician Copies of the standards listed above may be obtained from National Fire Protection Association ...

Страница 9: ...pply pressure for LP operation of the cooktop 1 Unscrew cap A on the pressure regulator 2 Turn it to the part where LP is printed 3 Re tighten it and lock the pins in the slots provided 4 There is an arrow printed on the back of the energy regulator The tip of the arrow indicates the end to be connected to the cooktop connector 4 Carefully position the insulation gasket supplied on the external pe...

Страница 10: ...o the hole on the inner side of the gasket The diagram below shows the exact positions of the holes to be used for clamping the hob to the top by the brackets correctly NOTE Use all of the brackets supplied with the appliance to fasten it to the support structure 6 Use pipe joint compound made for use with NATURAL and L P gas lf flexible metal connector is used be certain tubing is not kinked ...

Страница 11: ...is used be certain tubing is not kinked Use only pipes E conforming to standard regulations in force inserting gasket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas connection A before fixing the hob Always place a suitable sealing medium such as Teflon tape between pressure regulator D and adaptator C and between pressure regulator D and pipe E 8 Plug power suppl...

Страница 12: ... found on the cooktop These procedures must be repeated for each burner on the cooktop CAUTION refit all flame caps in the same points from which they were removed In fact the flame cap positions cannot be changed After refitting them ensure that they are fitted perfectly and that there is no clearance between the top and the flame caps 3 The cooktop s electrical circuit can be checked for proper ...

Страница 13: ...equipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing ...

Страница 14: ...with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing ...

Страница 15: ...with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing ...