Smeg PTS605 Скачать руководство пользователя страница 9

Instructions for the Installer

11

4. INSTALLING THE COOKTOP

1)

Remove the styrofoam protection and lift the cooktop in order to
extract it from the side protectors and the box.

2)

Fit the insulating gasket provided carefully around the outside edge of the hole made in the top as shown
below, pressing it down with your hands so that its entire surface fits snugly. Follow the dimensions
shown, depending on the model of cooktop to be installed, keeping in mind that on both models the long
front edge must be flush with the hole. Fasten the cooktop to the structure using the brackets 

provided.

Carefully trim off the excess edge of the gasket 

B

. The dimensions in the drawing below refer to the hole

on the inside edge 

of the gasket.

NOTE: 

 Use all of the brackets supplied with the appliance to fasten it to the support structure.

3)

Always use pipe-joint compound made for use with NATURAL GAS
and L.P. GAS between pressure regulator 

and (NPT) adaptor 

C

and between pressure regulator 

and pipe 

E

. If a flexible metal

conductor is used, make sure that the tubing is not kinked.
 
Use only pipes (

E

) conforming to the standard regulations in force,

inserting the gasket 

(supplied) between fitting 

 and adaptor 

C

.

The adaptor 

must be fitted on the gas connection 

before fixing

the cooktop.

Always place a suitable sealing medium (such as Teflon tape)
between pressure regulator 

and adaptor 

and between pressure

regulator 

and pipe 

E

.

WARNING: 

 The tightening torque of adaptor 

must not be greater than 1416.2 ozf-in.

Содержание PTS605

Страница 1: ...ately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Страница 2: ...des and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store...

Страница 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS PTS605 PTS727...

Страница 4: ...ktop is to be installed must be sealed The cabinet opening dimensions that are shown must be used The given dimensions are minimum clearances A grounded electrical supply is required See the 3 2 Elect...

Страница 5: ...0 mm 21 7 8 22 555 560 mm 18 13 16 19 478 482 mm 11 13 16 300 mm 2 50 mm 2 50 mm 13 16 2 20 50 mm 28 3 8 720 mm NOTE 13 330 mm is the maximum recommended upper cabinet depth Gas line opening Wall ever...

Страница 6: ...ected to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel...

Страница 7: ...g the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an oven t...

Страница 8: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Страница 9: ...ons in the drawing below refer to the hole on the inside edge of the gasket NOTE Use all of the brackets supplied with the appliance to fasten it to the support structure 3 Always use pipe joint compo...

Страница 10: ...ing is not kinked 5 Check that the fixing rings burners flame diffuser rings and pan stands are fitted correctly The burner pins A must be fitted into the recesses B in the flame diffuser ring The hol...

Страница 11: ...to the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after assembly has been completed and you have checked to ensure that all parts have been fitted properly 1...

Страница 12: ...nstructions for the Installer 14 6 WIRING DIAGRAMS The power cord on this appliance is equipped with a threee pronge polarized plug grounding which fits in standard three pronged grounding wall outlet...

Страница 13: ...tructions for the Installer 15 WARNING When servicing the controls label all wires prior to disconnection Wiring errors can cause improper and dangerous operation Verify proper operation after servici...

Отзывы: