Installation
29
EN
Burner and injector characteristics tables
5.7 Electrical connection
General information
Check the grid characteristics against the
data indicated on the plate.
The identification plate bearing the
technical data, serial number and brand
name is visibly positioned on the appliance.
Do not remove this plate for any reason.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
NG 1.0 kPA
AUX
RR
UR2 Int.
UR2 Ext.
Nominal gas consumption (MJ/h)
3.9
9.6
16.8
Injector (1/100 mm)
90
140
90
175
ULPG 2.75 kPa
AUX
RR
UR2 Int.
UR2 Ext.
Nominal gas consumption (MJ/h)
3.9
.9.6
18.3
Injector (1/100 mm)
54
85
50
100
Power voltage
Danger of electrocution
• Have the electrical connection
performed by authorised persons.
• Use personal protective equipment.
• The appliance must be connected to
earth in compliance with electrical
system safety standards.
• Disconnect the mains power supply.
• Do not pull the cable to remove the
plug.
• Use cables withstanding a temperature
of at least 90°C.
• The tightening torque of the screws of
the terminal supply wires must be 1.5 -
2 Nm.
Pass the power supply cable
through the back of the unit, taking
care that it does not touch the
bottom casing of the cooktop or
the oven (if any) installed
underneath it.