WARNING: For your safety, the information in this manual must be followed to minimize the risk

of fire or explosion, or to prevent property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not attempt to switch on any appliances.

Do not touch any electrical switches.

Do not use any phones in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

lf you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

INSTRUCTIONS FOR THE INSTALLER:

 these are intended for the 

qualified engineer

 who is able to

install, commission and test the appliance

3

1. IMPORTANT SAFETY INSTRUCTIONS ................................................................................. 4
2. COOKTOP MEASUREMENTS ............................................................................................... 5
3. POSITIONING THE COOKTOP AND LOCATION REQUIREMENTS .................................... 6

3.1 Gas supply requirements ................................................................................................................................ 8
3.2 Electrical requirements .................................................................................................................................... 9

4. INSTALLING THE COOKTOP ............................................................................................... 11
5. CHECKING OPERATION ...................................................................................................... 14
6. WIRING DIAGRAMS ............................................................................................................. 15

Содержание PGFU36X

Страница 1: ...g Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTRUCTIONS FOR THE INSTALLER these are intended for the qualified engineer who is able to install commission and test the appliance ...

Страница 2: ...rnment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not attempt to switch on any appliances Do not touch any e...

Страница 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS ...

Страница 4: ...d tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination use This type of ventilation system may cause ignition and combustion problems with the gas cooking appliance resulting in personal injury or unintended operation Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required ...

Страница 5: ...2 50 mm 2 50 mm 2 50 mm 35 15 16 914 mm NOTE 13 330 mm is the maximum recommended upper cabinet depth Gas line opening Wall everywhere 5 12 7 cm below underside of countertop Cabinet base everywhere within 6 15 2 cm from rear wall is recommended Grounded outlet Locate within 24 61 cm from the right rear corner of the cut out drawer ...

Страница 6: ...d to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition 2 If local codes permit a flexible metal appliance connector with the new AGA or CSAcertified design 4 5 feet 1 2 1 5 m long 1 2 or 3 4 ...

Страница 7: ...y closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an oven the gas pipe must not pass along the back of the oven as this may cause overheating 3 2 Electrical requirements WARNING ELECTRICAL SHOCK HAZARD Plug into a grounded 3 prong outlet Do not cut or...

Страница 8: ...NSI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the customer to have a properly polarized and grounded 3 prong outlet installed by a qualified electrician Copies of the standards listed above may be obtained from National Fire Protection Association ...

Страница 9: ...O CHECK FOR PROPER TIGHTNESS NEVER USE A FLAME Leak testing of the appliance shall be conducted according to the manufacturer s instructions The following procedures must be performed to adjust the gas supply pressure for LP operation of the cooktop 1 Unscrew cap A on the pressure regulator 2 Turn it to the part where LP is printed 3 Re tighten it and lock the pins in the slots provided 4 There is...

Страница 10: ...to secure the hob to the supporting structure adjusting it until perfectly horizontal Carefully trim off the excess edge of the gasket A pic 2 The dimensions in picture 2 below refer to the distance between the hole and the inside edge of the gasket Do not fit the brackets shown in pic 3 until the hob has been set in place 1 2 3 NOTE Use all of the brackets supplied with the appliance to fasten it...

Страница 11: ...gasket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas connection A before fixing the hob Always place a suitable sealing medium such as Teflon tape between pressure regulator D and adaptator C and between pressure regulator D and pipe E 6 Before turning on the burners make sure that the flame spreader crowns and respective caps are properly fitted in their housing...

Страница 12: ...d to the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after top assembly has been completed as and you have checked to ensure that all parts have been fitted properly 1 a spark must light on all burners when the knobs on the top are pressed 2 when each knob on the cooktop is pressed and turned to the low flame symbol the entire crown should light 3 lf burne...

Страница 13: ...equipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing ...