  3.2  Burner and nozzle characteristics table 

 
Burner 

Rated 

heating 

capacity 

(kW) 

 

LPG – G30/G31  30/37 mbar 

 

 

Nozzle 

diameter 

1/100 mm 

By-pass 

mm 

1/100 

Reduced 

flow rate 

(W) 

Flow rate 

g/h G30 

Flow rate 

g/h G31 

Auxiliary (1) 

1.05 

50 

27 (*) 

28 (**)

350 

76 

75 

Semi rapid (2) 

1.8 

65 

33 (*) 

32 (**)

450 

130 

128 

Rapid (3) 

2.3 

75 

43 (*) 

42 (**)

800 

166 

164 

Ultra rapid (4) 

3.5 

94 

63 

1.6 

253 

250 

*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown in
point “4.1 Regulation of minimum for natural gas”. 

 

 
Burner 

Rated 

heating 

capacity 

(kW) 

 

Natural gas – G20  20 mbar 

 

 

Nozzle diameter 

1/100 mm 

Reduced flow rate 

(W) 

Auxiliary (1) 

1.05 

72 

350 

Semi rapid (2) 

1.8 

97 

450 

Rapid (3) 

2.3 

103 

800 

Ultra rapid (4) 

3.5 

133 

1500 

 

 
Burner 
 

Rated  

heating 

capacity  

(kW) 

 

Town gas – G110  8 mbar 

 

 

Nozzle diameter 

1/100 mm 

Reduced flow rate 

(W) 

Auxiliary (1) 

1.05 

145 

350 

Semi rapid (2) 

1.8 

185 

450 

Rapid (3) 

2.3 

220 

800 

Ultra rapid (4) 

3.3 

290 

1500 

 

 

Values for town gas are based on category III 1a2H3+ appliances. 

 

 

  3.3  Arrangement of burners on cooking hob 

  

 

BURNERS 
 

Auxiliary   

Semi rapid  

3 Rapid 
4 Ultra 

rapid 

30 

Содержание PGF95-1

Страница 1: ...NTENANCE __________________________ 34 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL INSTRUCTIONS FOR THE INSTALLER these are...

Страница 2: ...VE THE PACKAGING MATERIALS UNATTENDED IN THE HOME ENVIRONMENT SEPARATE THE DIFFERENT WASTE MATERIALS FROM THE PACKAGING AND DELIVER THEM TO THE NEAREST COLLECTION CENTRE FOR RECYCLABLE WASTE REGULATIO...

Страница 3: ...OT USE COOKING RECEPTACLES THAT EXTEND BEYOND THE OUTSIDE PERIMETER OF THE HOB THE APPLIANCE IS DESIGNED FOR USE BY ADULTS DO NOT ALLOW CHILDREN TO GO NEAR OR PLAY WITH IT WHEN DISPOSING OF THE APPLIA...

Страница 4: ...1 figure to avoid damage from overheating Make sure there is a minimum of 750 mm between the gas rings and any shelf that may be installed directly above them Carefully position the gasket provided al...

Страница 5: ...Instructions for the installer 2 3 4 23...

Страница 6: ...etween the gas rings and any shelf that may be installed directly above them This type of appliance requires the worktop the dimensions of which are shown shown in figure 2 to be milled to a depth of...

Страница 7: ...y exceed 125 degrees C To avoid a hazard under bench access must be restricted Refer to installation instruction IMPORTANT when installing the appliance above a cupboard a dividing shelf as shown abov...

Страница 8: ...the appliance Do not use reducers adapters or shunts If the power cable is to be replaced the wire section on the new cable must not be less than 0 75 mm 2 3 x 0 75 cable bearing in mind that the end...

Страница 9: ...not to be blocked in any way The room must be suitably ventilated to avoid overheating or excess humidity produced by cooking after any prolonged use a window should be opened or the speed of any fan...

Страница 10: ...t provoke stress of any kind on the appliance Connection may be made by using biconicaladapter D with insertion of gasket C supplied Connection with flexible steel pipe use only flexible stainless ste...

Страница 11: ...d and the minimum flame adjusted on the gas taps To change the nozzles proceed as described below 3 1 Replacement of nozzles on the hob 1 Remove the grids and all the caps and flame spreader crowns 2...

Страница 12: ...ves marked and shown in point 4 1 Regulation of minimum for natural gas Burner Rated heating capacity kW Natural gas G20 20 mbar Nozzle diameter 1 100 mm Reduced flow rate W Auxiliary 1 1 05 72 350 Se...

Страница 13: ...urn the regulation screw inside or next to the gas tap pin depending on the model until you get a suitable minimum flame Replace the knob and check burner flame stability when you turn the knob quickl...

Страница 14: ...vice is fitted with electronic ignition Simply press and turn the knob counter clockwise to the high flame symbol until the burner is ignited In models with safety valve after ignition the knob has to...

Страница 15: ...sides see paragraph 5 3 Diameter of receptacles When water reaches boiling point lower the flame so that it does not boil over To avoid burns or damage to the worktop all receptacles or griddle plates...

Страница 16: ...c scourers or sharp scrapers be used they will damage the surface Use normal non abrasive products for steel and a wooden or plastic tool if necessary Rinse thoroughly and dry with a soft cloth or cha...

Отзывы: