Smeg PGF75SCU3 Скачать руководство пользователя страница 9

Instructions for the Installer

11

4. INSTALLING THE COOKTOP

1)

Remove the polystyrene support and lift the hob to extract it from
the side supports and the box.

2)

Connection to the gas mains may be made with a flexible metal
pipe and conforming to the provisions defined by current standard
regulations in force. USE A SOAPY SOLUTION TO CHECK FOR
PROPER TIGHTNESS.

NEVER USE A FLAME.

Leak testing of the appliance shall be conducted according to the
manufacturer’s instructions.

The following procedures must be performed to adjust the gas
supply pressure for LP operation of the cooktop:
1 Unscrew cap A on the pressure regulator
2 Turn it to the part where LP is printed
3 Re-tighten it and lock the pins in the slots provided.
4 There is an arrow printed on the back of the energy regulator.

The tip of the arrow indicates the end to be connected to the
cooktop connector.

Содержание PGF75SCU3

Страница 1: ...Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be perfo...

Страница 2: ...nment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do n...

Страница 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS...

Страница 4: ...ooktops is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See 3 2 Electrical requi...

Страница 5: ...2 50 mm 2 50 mm 2 50 mm 28 3 8 720 mm NOTE 13 330 mm is the maximum recommended upper cabinet depth Gas line opening Wall everywhere 5 12 7 cm below underside of countertop Cabinet base everywhere wi...

Страница 6: ...to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas...

Страница 7: ...closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an...

Страница 8: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Страница 9: ...CHECK FOR PROPER TIGHTNESS NEVER USE A FLAME Leak testing of the appliance shall be conducted according to the manufacturer s instructions The following procedures must be performed to adjust the gas...

Страница 10: ...o secure the hob to the supporting structure adjusting it until perfectly horizontal Carefully trim off the excess edge of the gasket A pic 2 The dimensions in picture 2 below refer to the distance be...

Страница 11: ...asket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas connection A before fixing the hob Always place a suitable sealing medium such as Teflon tape between pressure re...

Страница 12: ...to the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after top assembly has been completed as and you have checked to ensure that all parts have been fitted pr...

Страница 13: ...quipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring e...

Отзывы: