Installation
25
EN
3. Replace the burner nozzles using a 7 mm
socket wrench according to the gas to
be used (see "Nozzle and burner
specification tables").
4. Reposition the burners in their respective
housings.
Adjusting the minimum setting for natural
or town gas
1. Light the burner and turn it to the minimum
position.
2. Remove the knobs by pulling them
upwards.
3. Turn the regulating screw on the side of
the cock stem until a steady minimum
flame is achieved.
4. Refit the knob and verify that the burner
flame is stable.
5. Turn the knob rapidly from the maximum
to the minimum setting: The flame should
not go out. Repeat the operation on all
gas cocks.
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
cock rod clockwise all the way.
The nozzle tightening torque must
be no more than 3 Nm.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new gas.
The label is inserted inside the
nozzle pack (where present).