Installation
72
After having tightened the hose
connector(s), push the gas hose
6
onto the
hose connector and secure it with the clamp
5
that is compliant with the standard in
force.
Connection with a steel hose
Make the connection to the gas mains
using a continuous wall steel hose whose
specifications comply with the applicable
standard.
Carefully screw the connector
3
to the gas
connector
1
of the appliance, placing the
seal
2
between them.
Connection with a steel hose with
bayonet fitting
Carry out the connection to the gas mains
using a steel hose with bayonet fitting
compliant with B.S. 669. Apply insulating
material to the thread of the gas hose
connector
4
and then tighten the adapter
3
.
Screw the assembly to the movable
connector
1
of the appliance, placing the
supplied seal
2
between them.
Connection using a rubber hose
complying with current standards is
only permitted if the hose can be
inspected along its entire length.
The inside diameter of the hose
must be 8 mm for LPG and 13 mm
for Natural gas and Town gas.
Содержание Mista Aesthetic B601GMXI9
Страница 40: ......