16 

 
• “

CAUTION

: Accessible parts may become hot when used with cooking 

appliances.” 

MAINTENANCE 

  Switch off or unplug the appliance from the mains supply before carrying out 

any maintenance work. 

•  Clean and/or replace the Filters after the specified time period (Fire hazard). 
•  The Grease filters must be cleaned every 2 months of operation, or more 

frequently for particularly heavy usage, and can be washed in a dishwasher. 

•  The Activated charcoal filter is not washable and cannot be regenerated, 

and must be replaced approximately every 4 months of operation, or more 
frequently for particularly heavy usage.  

•  "Failure to carry out cleaning as indicated will result in a fire hazard". 
•  Clean the hood using a damp cloth and a neutral liquid detergent. 
 

The symbol   on the product or on its packaging indicates that this product 
may not be treated as household waste. Instead it shall be handed over to the 
applicable collection point for the recycling of electrical and electronic 
equipment. By ensuring this product is disposed of correctly, you will help 
prevent potential negative consequences for the environment and human 
health, which could otherwise be caused by inappropriate waste handling of 
this product. For more detailed information about recycling of this product, 
please contact your local city office, your household waste disposal service or 
the shop where you purchased the product. 

 

Содержание KSP120XE

Страница 1: ...ual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções Brugsvejledning Bruksanvisning Руководство по эксплуатации Instrukcja Obsługi Bruksanvisning Käyttöohje KSP60XE KSP90XE KSP120XE ...

Страница 2: ...RE CONSEILS ET SUGGESTIONS 23 CARACTERISTIQUES 26 INSTALLATION 28 UTILISATION 29 ENTRETIEN 30 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 32 CHARAKTERISTIKEN 35 MONTAGE 37 BEDIENUNG 38 WARTUNG 39 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES 41 EIGENSCHAPPEN 44 INSTALLATIE 46 GEBRUIK 47 ONDERHOUD 48 ÍNDICE CONSEJOS Y SUGERENCIAS 50 CARACTERÍSTICAS 53 INSTALACIÓN 55 USO 56 MANTENIMIENTO 57 IT EN FR DE NL E...

Страница 3: ...HOLD ANBEFALINGER OG FORSLAG 77 EGENSKAPER 80 INSTALLASJON 82 BRUK 83 VEDLIKEHOLD 84 УКАЗАТЕЛЬ СОВЕТЫ И РЕКОМЕНДАЦИИ 86 ХАРАКТЕРИСТИКИ 89 УСТАНОВКА 91 ЭКСПЛУАТАЦИЯ 92 УХОД 93 SPIS TREŚCI UWAGI I SUGESTIE 95 WŁAŚCIWOŚCI TECHNICZNE 98 INSTALACJA 100 UŻYTKOWANIE 101 KONSERWACJA 102 INNEHÅLL REKOMMENDATIONER OCH TIPS 104 EGENSKAPER 107 INSTALLATION 109 ANVÄNDING 110 UNDERHÅLL 111 PT DK NO RU PL SE ...

Страница 4: ...4 4 SISÄLTÖ OHJEET JA SUOSITUKSET 113 MITAT JA OSAT 116 ASENNUS 118 KÄYTTÖ 119 HUOLTO 120 اﻟﻔﻬﺮس ﺎت اﻗﺘﺮاﺣ و ﺎدات ارﺷ 122 ﺎﺋﺺ اﻟﺨﺼ 125 ﺐ اﻟﺘﺮآﻴ 127 ﺘﺨﺪام اﻻﺳ 128 ﻴﺎﻧﺔ اﻟﺼ ﺔ ﻋﻤﻠﻴ 129 FI SA ...

Страница 5: ...nect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm The route of the flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in orde...

Страница 6: ...rposes other than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance can be...

Страница 7: ...heavy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring thi...

Страница 8: ...mponents Ref Q ty Product Components 1 1 Hood Canopy complete with Controls Light Fan unit Filters 8 1 Directional Grille ø 125 mm 9 1 Reduction Flange ø 150 120 mm Ref Q ty Installation Components 12e 2 Screws 2 9 x 9 5 Washer under head Q ty Documentation 1 Instruction Manual 1 12e 8 9 ...

Страница 9: ...t bottom edge of the unit excluding any doors Remove grease filters Screw the hood canopy to the unit from the inside Loosen the screws fixing the spacers and adjust then to the correct position before fastening completely WARNING The Hood Canopy must be fitted into the Unit before it is fixed to the wall ...

Страница 10: ...may be positioned over the hood Insert the reducer flange 9 on the hood body outlet Connect the flange to the outlet on the shelf over the hood by using a flexible or rigid pipe ø120 mm Fix the pipe in position using sufficient pipe clamps not sup plied Fix the air outlet grid 8 on the recirculation air outlet by using the 2 screws 12e 2 9 x 9 5 provided Ensure that the activated charcoal filters ...

Страница 11: ...se it so that it pops out of its housing To turn the lights off push the dial back inwards returning it to the off position Motor Speed Adjustment Press the dial and release it so that it pops out of its housing then turn the dial to select one of the available suction speeds ...

Страница 12: ...filters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version These filters are not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently with heavy usage REPLACING THE ACTIVATED CHARCOAL FILTER Remov...

Страница 13: ...er Replace the snap on lamp cover Lamp Power W Socket Voltage V Dimension mm ILCOS Code 28 E14 220 240 104 x 35 HSGSB C UB 28 220 240 E14 20 G4 12 33 x 9 HSG C UB 20 12 G4 35 GU10 230 51 x 50 7 HAGS 35 230 GU10 51 40 50 GU10 230 51 x 50 7 HAGS 35 230 GU10 51 20 20 GU4 12 40 x 35 HRGS 20 12 GU4 35 30 20 GU5 3 12 46 x 51 HRGS 20 12 GU5 3 50 10 16 G13 95 720 x 26 FD 16 40 1B E G13 26 720 18 G13 57 58...

Отзывы: